Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHAVARRIA'S PLUMBING OF SAN ANTONIO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHAVARRIA'S PLUMBING OF SAN ANTONIO, INC. in 411 E. QUINCY ST., SAN ANTONIO, TX 78207 (NAICS 238220). OSHA activity number 343037644.

Watch Chavarria'S Plumbing OF SAN Antonio, INC. — free Get an email when a new federal OSHA severe-injury report for Chavarria'S Plumbing OF SAN Antonio, INC. is published. One employer, no account, unsubscribe in one click.
Site address
411 E. QUINCY ST.
City
SAN ANTONIO
State
TX
ZIP
78207
Mailing
P.O. BOX 593163, SAN ANTONIO, TX 78259
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $1000.00 Reduced
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:    On or about March 22, 2018, employees were exposed to a cave-in hazard, while preparing the bottom of the excavation for a grease trap installation, without a ladder for access.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1663

1926.651 J02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $1500.00 Reduced
29 CFR 1926.651(j)(2):   Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    On or about March 22, 2018, employees were exposed to a struck-by hazard while working inside and excavation with a spoil pile near the edge without any protection.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $1663

1926.651 K01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $0.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:    On or about March 22, 2018, employees were exposed to a cave-in hazard, while preparing the bottom of the excavation for a grease trap installation, without inspection by a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1663

1926.652 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):    On or about March 22, 2018, employees were exposed to a cave-in hazard while preparing the bottom of the excavation for a grease trap installation without a protective system in place.