Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JMC MASONRY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JMC MASONRY INC. in 4405 KLINGLE STREET NW, WASHINGTON, DC 20016 (NAICS 238140). OSHA activity number 343043097.

Watch JMC Masonry INC. — free Get an email when a new federal OSHA severe-injury report for JMC Masonry INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JMC MASONRY INC.
Site address
4405 KLINGLE STREET NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
7204 SUGAR MAPLE CT., ROCKVILLE, MD 20855
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2300.00 Reduced
29 CFR 1926.451(b)(1)(i): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).    a) On or about February 28, 2018; rear of residential home; the working platform of the scaffold system was not fully planked leaving an estimated 36-inch opening in which the employee could fall 14-feet to ground level.         In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3880

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2300.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) On or about February 28, 2018; rear area of the residential building; employees were not protected from falling 14-feet to ground level or 24-feet to basement area, while working on the scaffold system erected to remove the chimney system.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3880

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2300.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      a) On or about February 28, 2018; rear area of the building; employee while using a Bosch Hammer Drill, with chisel attachment, to chip away the concrete wall was exposed to a fall hazard of 10-feet to ground level.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $3880

1926.503 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about February 28, 2018; rear area; employee had not received fall protection from the current employee to include the hazards associated with the use of the fall protection equipment, alternatives, donning and proper use.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

MACY'S