LAS VEGAS, NV —
OSHA Inspection: ENVIRONMENTAL PROTECTION AGENCY - NATIONAL CENTER FOR RADIATION FIELD OPERATIONS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ENVIRONMENTAL PROTECTION AGENCY - NATIONAL CENTER FOR RADIATION FIELD OPERATIONS in 4220 S MARYLAND PARKWAY BUILDING C, LAS VEGAS, NV 89119 (NAICS 624230). OSHA activity number 343048328.
Where did this inspection happen?
- Site address
- 4220 S MARYLAND PARKWAY BUILDING C
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89119
- Mailing
- 4220 S MARYLAND PARKWAY BUILDING C, LAS VEGAS, NV 89119
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 624230
- Employees
- 21
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.304 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: Employees working in or near Building C room 624c were exposed to fire and smoke inhalation hazards in that a re-locatable power tap was being used to power a KEURIG coffee maker for which the equipment was not rated.
Recent events (1)
- — Z (S) $0
1910.305 D02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Employees working in or near the electronics shop panel 1LE1 were exposed to electrical shock, fire, and smoke inhalation hazards in that the electrical panel dead front allowed access to live parts.
Recent events (1)
- — Z (S) $0
1910.1200 F06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6): 29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: Employees working in or near Building E flammable liquids cabinet were exposed to fire and smoke inhalation hazards in that a water bottle containing a blue liquid thought to be hydraulic fluid was not labeled.
Recent events (1)
- — Z (S) $0
More inspections at ENVIRONMENTAL PROTECTION AGENCY - NATIONAL CENTER FOR RADIATION FIELD OPERATIONS
LAS VEGAS, NV—2022-05-17 00:00:00
ENVIRONMENTAL PROTECTION AGENCY - NATIONAL CENTER FOR RADIATION FIELD OPERATIONS
LAS VEGAS, NV—2022-05-17 00:00:00
ENVIRONMENTAL PROTECTION AGENCY - NATIONAL CENTER FOR RADIATION FIELD OPERATIONS
More inspections in this industry (NAICS 624230)
SEATTLE, WA—2026-05-12
WA317991210 - DOWNTOWN EMERGENCY SERVICE CEN
CHRISTIANSTED, VI—2026-04-24
OFFICE OF DISASTER RECOVERY
ERIN, TN—2026-04-16
HOUSTON COUNTY - 911 CENTRAL COMMUNICATIONS
HONOLULU, HI—2026-04-15
C&C - HESD, OCEAN SAFETY AND LIFEGUARD SERVICES DIVISION, DISTRICT 5
CHESAPEAKE, VA—2026-03-05
FAST TRACK EMS, LLC
More inspections in NV
CARSON CITY, NV—2026-07-13
JIFFY AIR TOOL
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
LAS VEGAS, NV—2026-07-13
THE BERKLEY LAS VEGAS
RENO, NV—2026-07-10
AMUNDSON ROOFING, INC.
LAS VEGAS, NV—2026-07-09
CENTENNIAL MMA, LLC
Source