MARINETTE, WI —
OSHA Inspection: FINCANTIERI MARINE GROUP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FINCANTIERI MARINE GROUP, LLC in 1600 ELY STREET, MARINETTE, WI 54143 (NAICS 336611). OSHA activity number 343051819.
Where did this inspection happen?
- Establishment
- FINCANTIERI MARINE GROUP, LLC
- Site address
- 1600 ELY STREET
- City
- MARINETTE
- State
- WI
- ZIP
- 54143
- Mailing
- 1600 ELY STREET, MARINETTE, WI 54143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 1500
- Ownership type
- A
Citations
5 citations on file for this inspection.
1915.13 B09
- Issued
- Abate by
- Penalty
- Initial $10163.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1915.13(b)(9): Only explosion-proof, self-contained portable lamps, or other electric equipment approved by a National Recognized Testing Laboratory (NRTL) for the hazardous location shall be used in spaces described in paragraph (a) of this section until such spaces have been certified as "Safe for Workers": (Note to paragraph (b)(9): Battery-fed, portable lamps or other electric equipment bearing the approval of a NRTL for the class, and division of the location in which they are used are deemed to meet the requirements of this paragraph.) a) On or about March 7, 2018, a Coating Department employee entered Fuel Tank 5-37-1-F on LCS 15 with an electric vacuum not designed for use in hazardous locations and used the vacuum while performing the Final Cleaning work procedures of Fuel Tank 5-37-1-F. Fuel had been added to LCS 15 on March 6, 2018 and Fuel Tank 5-37-1-F was not disconnected, blanked off, or otherwise blocked by a positive method from the fuel transfer system to prevent fuel from entering Fuel tank 5-37-1-F.
Recent events (2)
- — I (S) $0
- — Z (S) $10163
1915.15 A
- Issued
- Abate by
- Penalty
- Initial $10163.00 · Current $9999.00 Reduced
General-duty citation text
29 CFR 1915.15(a): Preventing hazardous materials from entering. Pipelines that could carry hazardous materials into spaces that have been certified "Safe for Workers" or "Safe for Hot Work" shall be disconnected, blanked off, or otherwise blocked by a positive method to prevent hazardous materials from being discharged into the space: a) On or about March 7, 2018, Fuel Tank 5-37-1-F was certified "Safe for Workers" when the pipelines connecting Fuel Tank 5-37-1-F to the LCS 15 Fuel System had not been disconnected, blanked off, or otherwise blocked by a positive method when fuel had been added to the LCS 15 Fuel System on March 6, 2018.
Recent events (2)
- — I (S) $9999
- — Z (S) $10163
1915.163 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.163(a)(1): The isolation and shutoff valves connecting the dead system with the live system or systems shall be secured, blanked, and then locked or tagged, in accordance with �� 1915.89, indicating that employees are working on the systems. The lock or tag shall not be removed or the valves unblanked until it is determined that this may be done without creating a hazard to the employees working on the system, or until the work on the system is completed, in accordance with �� 1915.89. When valves are welded instead of bolted, at least two isolation and shutoff valves connecting the dead system with the live system or systems shall be secured, and then locked or tagged, in accordance with �� 1915.89. a) On or about March 7, 2018, the employer's usage of valve FT-V-40 to isolate Fuel Tank 5-37-1-F from the LCS 15 Fuel System during the Fuel Transfer Pump test did not meet the requirement of, at least, two isolation and shutoff valves being secured to isolate a section of a piping system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.15 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.15(b): Alteration of existing conditions. When a change that could alter conditions within a tested confined or enclosed space or other dangerous atmosphere occurs, work in the affected space or area shall be stopped. Work may not be resumed until the affected space or area is visually inspected and retested and found to comply with 1915.12, 1915.13, and 1915.14 of this part, as applicable: (Note to paragraph (b): Examples of changes that would warrant the stoppage of work include: The opening of manholes or other closures or the adjusting of a valve regulating the flow of hazardous materials.) a) On or about March 6, 2018, Fuel Tank 5-37-1-F was not re-evaluated to determine Fuel Tank 5-37-1-F had been disconnected, blanked off or otherwise blocked by a positive method from the LCS 15 Fuel System after fuel was added to the vessel when a Coating Department employee had been assigned to perform Final Cleaning work tasks in Fuel Tank 5-37-1-F on or about March 7, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.89 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.89(g)(1): Before servicing machinery, equipment, or a system that has a lockout/tags-plus system, the employer shall ensure that the authorized employee, or the primary authorized employee in a group lockout/tags-plus application, verifies that the machinery, equipment, or system is deenergized and all energy sources isolated: a) On or about March 7, 2018, a Coating Department employee was not notified of a new energy control verification requirement while entering Fuel Tank 5-37-1-F on LCS 15 to perform Final Cleaning work tasks. The Coating Department employee had received a Tank Re-entry Form indicating no lockout procedure was required to enter the Fuel Tank 5-37-1-F on or about March 1, 2018. On or about March 6, 2018, fuel was added to the LCS 15 Fuel System and Fuel Tank 5-37-1-F had not been disconnected, blanked off, or otherwise blocked by a positive method to prevent fuel entering the Fuel Tank 5-37-1-F during and/or after the ship fueling.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at FINCANTIERI MARINE GROUP, LLC
MARINETTE, WI—2025-06-10
FINCANTIERI MARINE GROUP, LLC
STURGEON BAY, WI—2025-03-11
FINCANTIERI MARINE GROUP, LLC
STURGEON BAY, WI—2025-01-02
FINCANTIERI MARINE GROUP, LLC
STURGEON BAY, WI—2024-09-10 00:00:00
FINCANTIERI MARINE GROUP, LLC
STURGEON BAY, WI—2023-08-10 00:00:00
FINCANTIERI MARINE GROUP, LLC
View FINCANTIERI MARINE GROUP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
NORTH CHARLESTON, SC—2026-07-14
DETYENS SHIPYARDS, INC.
KINGSFORD, MI—2026-07-14
LAKE SHORE SYSTEMS, INC DBA TRIDENT MARITIME SYSTEMS
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
PORTSMOUTH, VA—2026-07-09
PALFINGER MARINE USA INC.
STUART, FL—2026-07-07
APPLIED CONCEPTS UNLEASHED, INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343051819.