WESTWOOD, MA —
OSHA Inspection: JEM CONSTRUCTION CO, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JEM CONSTRUCTION CO, INC in 46 WASHINGTON STREET, WESTWOOD, MA 02090 (NAICS 238130). OSHA activity number 343055109.
Where did this inspection happen?
- Establishment
- JEM CONSTRUCTION CO, INC
- Site address
- 46 WASHINGTON STREET
- City
- WESTWOOD
- State
- MA
- ZIP
- 02090
- Mailing
- 16 CLEMATIS AVENUE, WEYMOUTH, MA 02188
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $1885.00 · Current $943.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. Jobsite: Employees were not provided and required to wear safety glasses while operating saws and nail guns during wood framing operations where there was potential to be hit with flying particles.
Recent events (2)
- — I (S) $942.5
- — Z (S) $1885
1926.501 B13
- Issued
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Jobsite: a) A employees was exposed to a fall hazard over 20 feet from ground level while working on the pitch roof and a fall hazard over 8 feet from ground level while working on flat roof during framing operations. b) Employees were exposed to a fall hazard from a floor opening approximately 10 feet down to basement level without a fall protection system in place.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $1109.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Jobsite: Employer did not ensure all employees who worked at heights over 6 feet high during framing operations were trained on fall protection hazards and methods to protect themselves from falls.
Recent events (2)
- — I (S) $1108.5
- — Z (S) $2217
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: Jobsite: Employer did not verify that all employees who worked at heights over 6 feet high during framing operations were trained on fall protection hazards and methods to protect themselves from falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1051 A
- Issued
- Penalty
- Initial $1663.00 · Current $832.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. Jobsite Front Entrance: One of the entrances into the building did not have a stairway constructed, where there was a 51 inch break in elevation.
Recent events (2)
- — I (S) $831.5
- — Z (S) $1663
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343055109.