Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JZ EXCAVATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JZ EXCAVATION in 311 NICHOLS ST., FORT WORTH, TX 76111 (NAICS 238910). OSHA activity number 343064937.

Watch JZ Excavation — free Get an email when a new federal OSHA severe-injury report for JZ Excavation is published. One employer, no account, unsubscribe in one click.
Establishment
JZ EXCAVATION
Site address
311 NICHOLS ST.
City
FORT WORTH
State
TX
ZIP
76111
Mailing
166 RA MAGEE RD., DRY PRONG, LA 71423
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1272.00 · Current $1272.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.     At a work place located at 311 Nichols St., Fort Worth, Texas: an employee was not provided a safe means of egress from approximately 13-foot deep excavation while checking on sewage pipes and was exposed to cave-in and crush-by hazards.
Recent events (1)
  • — Z (S) $1272

1926.651 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1696.00 · Current $1696.00
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation.     At a work place located at 311 Nichols St., Fort Worth, Texas: an employee working in a 13-foot deep excavation where water was accumulating was not protected from the hazards of cave-in.
Recent events (1)
  • — Z (S) $1696

1926.651 J02

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1413.00 · Current $1413.00
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.      At a work place located at 311 Nichols St., Fort Worth, Texas: the employer did not ensure the operator digging the trench place the loose soil 2 feet away from the edge of the trench exposing employees to the hazards of cave-in.
Recent events (1)
  • — Z (S) $1413

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2120.00 · Current $2120.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).   At a trench on 311 Nichols St, Fort Worth, Texas:  an employee was exposed to cave-in hazards while checking on a sewer line inside a 13 feet depth trench with vertical walls on all sides and no protective system.
Recent events (1)
  • — Z (S) $2120

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343064937.