Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PIMS NEW JERSEY, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PIMS NEW JERSEY, INC in 510 RYERSON RD., UNIT 1B, LINCOLN PARK, NJ 07035 (NAICS 561910). OSHA activity number 343073789.

Watch Pims NEW Jersey, INC — free Get an email when a new federal OSHA severe-injury report for Pims NEW Jersey, INC is published. One employer, no account, unsubscribe in one click.
Site address
510 RYERSON RD., UNIT 1B
City
LINCOLN PARK
State
NJ
ZIP
07035
Mailing
510 RYERSON RD., UNIT 1B, LINCOLN PARK, NJ 07035
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
32
Ownership type
A

6 citations on file for this inspection.

1910.37 B05

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    Location: 510 Ryerson Rd., Lincoln Park, NJ.    a) A door along the exit route was not marked "Not an Exit" at the establishment's packaging area;  on or about 4/3/18.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

1910.110 F02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1910.110(f)(2)(ii): Containers when stored near exits, stairways, or in areas normally used or intended for the safe exit of people.    Location: 510 Ryerson Rd., Lincoln Park, NJ.    a) A propane tank was stored near the emergency exit;  on or about 4/23/18.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

1910.219 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $9054.00 · Current $6850.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).    Location: 510 Ryerson Rd., Lincoln Park, NJ.    a) The Polybag machine utilized by an employee did not have a guard thereby exposing the employee to moving parts; on or about 4/3/18.
Recent events (2)
  • — I (S) $6850
  • — Z (S) $9054

1910.219 E01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o).  Location: 510 Ryerson Rd., Lincoln Park, NJ.  a) The Polybag machine utilized by an employee did not have a guard thereby exposing the employee to moving parts; on or about 4/3/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $9054.00 · Current $5000.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision.    Location: 510 Ryerson Rd., Lincoln Park, NJ.    a) The polybag machine's live parts and/or electrical wiring did not have an enclosure. An employee was exposed to electrical shock; on or about 4/3/18.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9054

1910.305 G01 IV A

Serious Gravity 1 2 instances 5 exposed
Issued
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    Location: 510 Ryerson Rd., Lincoln Park, NJ.    a) Employer utilized temporary extension cords as a permanent connection to power the Polybag machine and the fill-pack TT/ran-pack machine.  The extension cords were not used as specified as employer used it to capacity daily thereby increasing overheating and thus creating a potential fire hazard at the facility; on or about 4/3/18.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343073789.