WASHINGTON, DC —
OSHA Inspection: DISTRICT CONSTRUCTION INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DISTRICT CONSTRUCTION INC. in 2000 CONSTITUTION AVE., NW, WASHINGTON, DC 20005 (NAICS 236220). OSHA activity number 343074019.
Where did this inspection happen?
- Establishment
- DISTRICT CONSTRUCTION INC.
- Site address
- 2000 CONSTITUTION AVE., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20005
- Mailing
- 107 S. WEST ST., #824, ALEXANDRIA, VA 22314
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.251 C04 III
- Issued
- Abate by
- Penalty
- Initial $5173.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.251(c)(4)(iii): Eyes in wire rope bridles, slings or bull wires were formed by wire rope clips or knots: a) Basement, Area Way - On or about April 5, 2018, workers were exposed to a struck-by hazard when a 500 lbs. portable conveyor system was suspended aloft by means of rigging where a 3/8 inch wire rope was formed into an eye by using wire rope clamps. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $5173
- — Z (S) $5173
1926.651 K02
- Issued
- Abate by
- Penalty
- Initial $3141.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) Basement, Area Way - On or about March 15, 2018, workers were removing a portion of a concrete beam while occupying a 14 feet deep excavation comprised of Class B soil, having vertical walls on two sides, and a third wall which was not adequately sloped, with no protective systems in place. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $0
- — C (S) $3141
- — Z (S) $3141
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) Basement Area Way - On or about March 15, 2018, workers were exposed to unexpected cave-ins from the unprotected excavation which was 14 feet deep, consisted of Class B soil, had vertical walls on two sides and a third wall which was not adequately sloped. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.701 B
- Issued
- Penalty
- Initial $5173.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a) Stairway at Intersection of Column line 2 and 11 - Workers were exposed to an impalement hazard from #4 rebar dowels which projected 2 feet (vertically) above a concrete floor slab and were not guarded. No abatement certification or documentation required for this item.
Recent events (3)
- — F (S) $0
- — C (S) $5173
- — Z (S) $5173
1926.1053 B01
- Issued
- Penalty
- Initial $3141.00 · Current $7000.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) Mechanical Room, Stair 1 - On or about April 5, 2018, workers were exposed to an 8 foot fall hazard for the top of a portable step ladder that extended only 2 feet above the ladder landing, was not secured in place, and was not provided with a grabrail. No abatement certification or documentation required for this item.
Recent events (3)
- — F (O) $7000
- — C (S) $3141
- — Z (S) $3141
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Mechanical Room, Stair 1 - On or about April 5, 2018, workers were exposed to an 8 foot fall hazard while using a 10 foot portable step ladder which was unopened and leaned against the edge of a concrete slab to access their work area. No abatement certification or documentation required for this item.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343074019.