SEVERANCE, CO —
OSHA Inspection: POWERS BUILT STRUCTURES, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of POWERS BUILT STRUCTURES, INC. in WCSD4 SEVERANCE HIGH SCHOOL 1200 HIDDEN VALLEY PARKWAY, SEVERANCE, CO 80546 (NAICS 238120). OSHA activity number 343075487.
Where did this inspection happen?
- Establishment
- POWERS BUILT STRUCTURES, INC.
- Site address
- WCSD4 SEVERANCE HIGH SCHOOL 1200 HIDDEN VALLEY PARKWAY
- City
- SEVERANCE
- State
- CO
- ZIP
- 80546
- Mailing
- P.O. BOX 479, HUDSON, CO 80642
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $5821.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person(s) designated by the employers in the following instances: a) Powers Built Structures, Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: On or before April 4, 2018, the employer did not ensure that competent person inspections were performed on the steel erection of the west staircase in Area E. Erection aid tabs used to connect the west and north horizontal tube steel beams to the columns were not designed, rated, and approved by a qualified engineer. In addition, these erection aid tabs were tack welded to the west columns, and this welding was not inspected by a qualified weld inspector. The employer did not ensure that competent person inspections were performed of the steel erection process of the west staircase of Area E; b) Powers Built Structures, Inc. Sampson Construction Co., Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: At approximately 7:10 am on April 4, 2018, while setting up to pump concrete, a concrete pump truck boom struck the upper horizontal tube steel beam on the west side of the staircase in Area E. The employer did not ensure that a competent person inspected the beam and its supports after this first strike, and before continuing with concrete pumping operations. At approximately 10:10 am, a concrete pump truck struck the west upper horizontal tube steel beam with its boom a second time. The beam fell and struck an employee of the concrete delivery company, resulting in fatal injuries. These conditions exposed subcontractor employees to the hazard of being struck-by falling steel beams.
Recent events (3)
- — F (S) $0
- — C (S) $5821
- — Z (S) $5821
1926.754 A
- Issued
- Abate by
- Penalty
- Initial $5821.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.754(a): Structural stability was not maintained at all times during the erection process: a) Powers Built Structures, Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: On and before April 4, 2018, the employer did not ensure that structural stability was maintained at all times during the erection process, in that two horizontal beams along the west staircase of Area E were not structurally stable. Erection aid tabs used to connect the west and north horizontal tube steel beams to the west columns were not designed, rated, and approved by a qualified engineer. In addition, these erection aid tabs were tack welded to the west columns, and this welding was not inspected by a qualified weld inspector. The employer did not ensure that structural stability was maintained at all times during the steel erection process. This condition exposed employees, and employees of other contractors, to the hazard of being struck-by falling steel.
Recent events (3)
- — F (S) $0
- — C (S) $5821
- — Z (S) $5821
More inspections at POWERS BUILT STRUCTURES, INC.
CHEYENNE, WY—2019-08-27 00:00:00
POWERS BUILT STRUCTURES, INC
ENGLEWOOD, CO—2016-05-25 00:00:00
POWERS BUILT STRUCTURES, INC
DENVER, CO—2013-04-29 00:00:00
POWERS BUILT STRUCTURES, INC.
View POWERS BUILT STRUCTURES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
CHESAPEAKE, VA—2026-07-08
MODERN STEEL AND STAIR LLC
YAKIMA, WA—2026-07-07
WA317991949 - H & A STEEL ERECTORS LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343075487.