PHILLIPS, WI —
OSHA Inspection: PLEIN MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PLEIN MANUFACTURING in N8038 STATE HWY 13 P.O. BOX 211, PHILLIPS, WI 54555 (NAICS 321920). OSHA activity number 343080818.
Where did this inspection happen?
- Establishment
- PLEIN MANUFACTURING
- Site address
- N8038 STATE HWY 13 P.O. BOX 211
- City
- PHILLIPS
- State
- WI
- ZIP
- 54555
- Mailing
- N8038 STATE HWY 13 P.O. BOX 211, PHILLIPS, WI 54555
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Go-Fast Band Resaw; A program for the control of hazardous energy sources was not developed by the employer for employees who perform set-up, cleaning, blade changes, jam clearing, and cleaning of the saw.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Go-Fast Band Resaw; The employer did not ensure that all devices which isolated hazardous energy were located and isolated prior to set-up, cleaning, jam clearing, and blade changes being performed.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Go-Fast Band Resaw; The employer did not ensure that locks were affixed to prevent the release of hazardous energy prior to set-up, cleaning, jam clearing, and blade changes being performed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1940.00 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut to give maximum protection possible for the operation being performed: (a) Throughout the production area; The employer did not ensure that the lower exposed portion of the blades were guarded to the full diameter on radial saws.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1910.213 H03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(h)(3): Radial saw(s) were not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations: (a) Throughout the production area; The employer did not ensure that the radial saws at the facility had an adjustable stop in place to ensure the saws forward travel was limited to position necessary to complete the cut.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: (a) Throughout the production area; The employer did not ensure that the radial saws at the facility were installed correctly to ensure the cutting head returned to the starting position when released.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) Throughout the production area; The employer did not provide certification that the different work areas at the facility have been evaluated to determine the adequate type of personal protective equipment (PPE).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321920)
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
WASHINGTON COURT HOUSE, OH—2026-07-09
HALLIDAY LUMBER, LLC
HENDERSON, TX—2026-06-30
W.D. TOWNLEY AND SON LUMBER COMPANY, INC.
BOYCEVILLE, WI—2026-06-26
SPECIALTY MANUFACTURING OF MENOMONIE, LLC
JACKSONVILLE, FL—2026-06-25
CHEP SERVICES, LLC
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343080818.