Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILLIMANSETT WASTE CO INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WILLIMANSETT WASTE CO INC in 239 NARRAGANSETT BLVD., CHICOPEE, MA 01013 (NAICS 423930). OSHA activity number 343087557.

Watch Willimansett Waste CO INC — free Get an email when a new federal OSHA severe-injury report for Willimansett Waste CO INC is published. One employer, no account, unsubscribe in one click.
Site address
239 NARRAGANSETT BLVD.
City
CHICOPEE
State
MA
ZIP
01013
Mailing
239 NARRAGANSETT BLVD., CHICOPEE, MA 01013
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3622.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:       239 Narragansett Blvd, Chicopee, MA    On May 23, 2018 and at times prior, the employer's energy control procedures were not used by employees who performed maintenance and servicing activities.    a. Employees and managers who set up the alligator shear for use or cleaning did not follow the procedure when they added a wood block to protect against a second source of hazardous energy not identified in the procedure.    b. On April 13, 2018 and at times prior, employees who reached inside the horizontal bailer did not utilize the procedure and were exposed to crushed-by hazards.  The employees did not have exclusive control of the lockout device due to the lockout key being left attached by chain to the machine.
Recent events (2)
  • — I (S) $3622
  • — Z (S) $5174

1910.147 C06 I

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  239 Narragansett Blvd, Chicopee, MA  As of May 23, 2018, the employer had not performed a periodic inspection that ensured each procedure was inspected for inaccuracies during an actual energy control task and did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    239 Narragansett Blvd, Chicopee, MA    On April 13, 2018 and at times prior, the employer provided verbal on-the-job energy control training to authorized and affected employees.  The employer did not train employees on the written energy control program procedures and an employee did not understand the safe usage of energy controls.   The employee was exposed to crushed-by hazards due to a lack of exclusive control of a bailer lockout device; the lockout device key was attached by a chain to the machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

1910.147 C07 IV

Serious Gravity 1 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify by each employee's name and dates of training that employee training had been accomplished and kept up to date:        239 Narragansett Blvd, Chicopee, MA    On April 13, 2018 and at times prior, the employer had no certification for the verbal energy control training that had been provided to authorized, affected, and other employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3623.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     239 Narragansett Blvd, Chicopee, MA    On April 9, 2018 and at times prior, employees who operated the Gensco Alligator Shear were exposed to laceration and amputation hazards.  The blade guard was inoperative and unable to be adjusted fully downward; the guard would have allowed access to the danger zone even at full adjustment.  On April 9, 2018, an employee received an amputation injury while operating the alligator shear.
Recent events (2)
  • — I (S) $3623
  • — Z (S) $5174