OSHA Inspection: DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, NATIONAL FIRST LADIES LIBRARY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE, NATIONAL FIRST LADIES LIBRARY in 205 MARKET AVE S, CANTON, OH 44702 (NAICS 712190). OSHA activity number 343093662.

Watch Department OF Interior, National Park Service, National First Ladies Library — free Get an email when a new federal OSHA severe-injury report for Department OF Interior, National Park Service, National First Ladies Library is published. One employer, no account, unsubscribe in one click.
Site address
205 MARKET AVE S
City
CANTON
State
OH
ZIP
44702
Mailing
15610 VAUGHN ROAD ATTN: LOIS NEFF, BRECKSVILLE, OH 44141
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
2
Ownership type
D

12 citations on file for this inspection.

1910.30 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.30(a)(1) as required by 1960.8 (b): Before any employee is exposed to a fall hazard, the employer must provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart. Employers must ensure employees are trained in the requirements of this paragraph 1910.30(a)(1) through 1910.30 (a)(3)(IV) on or before May 17, 2017.      On or about April 18, 2018 the employer did not provide fall hazard training as required for employees who are required to go onto the roof top, to perform maintenance work. The roof top is approximately 60 feet high.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2) as required by 1960.8 (b):  The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  On or about April 18, 2018 the employer had not documented that a workplace hazard assessment had been conducted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(i) as required by 1960.8 (b): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:  On or about April 18, 2018 the employer failed to ensure that employees who were exposed to live parts while trouble shooting/voltage testing and working on energized electrical parts on voltages up to 120 were not using electrical protective equipment for the hands and arms. Employees were not provided with voltage insulated rated gloves and arm sleeves to protect the employees from hazards associated with electrocution, arc flash, and arc blast.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.140 C13 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.140(c)(13)(ii) as required by 1960.8 (b): Anchorages must be designed, installed, and used, under the supervision of qualified person, as part of a complete personal fall protection system that maintains a safety factor of at least two.  On or about April 18, 2018 the employer failed to have anchorages installed on the roof for employees to tie off to when performing maintenance work on the roof top.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.140 C18

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.140(c)(18) as required by 1960.8 (b): Personal fall protection systems must be inspected before initial use during each workshift for mildew, wear, damage, and other deterioration, and defective components must be removed from service.  On or about April 18, 2018, the employer failed to ensure that employees were inspecting their personal fall arrest system (PFAS) before use. The employees use their PFAS to do work on the roof top that is approximately 60 feet high.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(i) as required by 1960.8 (b): : Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about April 18, 2018 the employer failed to ensure that equipment maintained and serviced by employees had machine specific procedures developed for the control of hazardous energies. Energy sources included, but are not limited to, electrical, thermal, and pneumatic. Employees are tasked with maintaining, servicing, and operating equipment including but not limited to the exhaust fans, HVAC systems, and heaters in the spouting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i) as required by 1960.8 (b): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    On or about April 18, 2018 the employer failed to ensure that employees were trained on the control of hazardous energies. Employees tasked with the LO/TO of equipment for maintaining and servicing had not received authorized training. Employees tasked with operating and working near equipment had not received affected training. Energy sources included, but are not limited to, electrical, pneumatic, and thermal. Employees are tasked with maintaining, servicing, and operating equipment including but not limited to the exhaust fans, HVAC systems, and heaters in the spouting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.332(b)(1) as required by 1960.8 (b): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  On or about April 18, 2018, the employer did not provide safety related work practices training to the employee who was designated to operate, maintain, and repair electrical equipment at the National First Ladies Library there by exposing employee to electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(a)(1) as required by 1960.8 (b): Live parts to which an employee was exposed were not deenergized before the employee worked on or near them:  On or about April 18, 2018 an employee working on live parts on an electrical panel box that was  located on the sixth floor, was not de energized. The employee was changing out a circuit breaker in the electrical panel box with a GFCI breaker.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1) as required by 1960.8 (b): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about April 18, 2018 the employer failed to develop or implement a written hazard communication program at the facility. Employees are exposed to hazardous chemicals including but not limited to oils, lubricants, refrigerant, and various cleaning supplies.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1) as required by 1960.8 (b):  The employer did not have a material safety data sheet for each hazardous chemical in use  On or about April 18,2018 the employer did not ensure that safety data sheets were readily accessible during each work shift in that employees did not know where the Safety Data Sheets were located.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1) as required by 1960.8 (b): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    On or about April 18, 2018 the employer failed to train employees on the safe use and handling of hazardous chemicals used in the workplace. Employees are exposed to hazardous chemicals including but not limited to propane and lubricants.
Recent events (2)
  • — I (S) $0