Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PIMMEX

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PIMMEX in CHINLE EDERLY CARE RENOVATION, #170298, CHINLE, AZ 86503 (NAICS 236115). OSHA activity number 343102109.

Watch Pimmex — free Get an email when a new federal OSHA severe-injury report for Pimmex is published. One employer, no account, unsubscribe in one click.
Establishment
PIMMEX
Site address
CHINLE EDERLY CARE RENOVATION, #170298
City
CHINLE
State
AZ
ZIP
86503
Mailing
6640 W. SUNDUST DRIVE P.O. BOX 5024, CHANDLER, AZ 85226
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3298.00 · Current $3298.00
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.   Chinle Elderly Care Renovation, #170298:  The employer did not ensure that a painter spraying interior walls with acrylic latex paint was wearing eye protection.
Recent events (1)
  • — Z (S) $3298

1910.134 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103)   Chinle Elderly Care Renovation, #170298:  The employer did not provide a painter supplying his own 3M tight fitting respirator with Appendix D of this standard as required.
Recent events (1)
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:   Chinle Elderly Care Renovation, #170298:  A painter donning a 3M tight fitting respirator to protect him from paint over spray hazards had a moustache.
Recent events (1)
  • — Z (S) $0

1910.134 G01 I B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function: (Construction Reference 1926.103)   Chinle Elderly Care Renovation, #170298:  A painter was observed wearing a disposable 3M 8210 dust mask underneath his 3M tight fitting respirator to protect him against acrylic latex paint over spray and vapor.  The dust mask interferes with the face-to-facepiece seal reducing the protection factors of the tight fitting respirator.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343102109.