Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUNFORD REFRIGERATION, HEATING & AIR CONDITIONING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUNFORD REFRIGERATION, HEATING & AIR CONDITIONING, INC. in 820 US HIGHWAY 9 (WENDYS), AVENEL, NJ 07001 (NAICS 238220). OSHA activity number 343116463.

Watch Dunford Refrigeration, Heating & AIR Conditioning, INC. — free Get an email when a new federal OSHA severe-injury report for Dunford Refrigeration, Heating & AIR Conditioning, INC. is published. One employer, no account, unsubscribe in one click.
Site address
820 US HIGHWAY 9 (WENDYS)
City
AVENEL
State
NJ
ZIP
07001
Mailing
160 LIBERTY STREET, # D, METUCHEN, NJ 08840
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.1053 B04

Serious Gravity 5 3 instances 2 exposed
Issued
Penalty
Initial $3326.00 · Current $2328.00 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed:        a. 820 US Highway 9, Avenel, NJ - Wendy's    Employees engaged in commercial HVAC installation activities used a 12-foot Werner A-frame ladder in a manner not intended by the manufacturer. Employees used the A-Frame ladder in the closed position as a means of access from ground level to the roof of the coolers.    Violation observed on or about April 26, 2018    b. 820 US Highway 9, Avenel, NJ - Wendy's    Employees engaged in commercial HVAC installation activities used a 12-foot Werner A-frame ladder in a manner not intended by the manufacturer. Employees used the A-Frame ladder in the closed position as a means of access from the roof of the coolers to the top of the parapet wall.    Violation observed on or about April 26, 2018    c. 820 US Highway 9, Avenel, NJ - Wendy's    Employees engaged in commercial HVAC installation activities used a 4-foot Werner A-frame ladder in a manner not intended by the manufacturer. Employees used the A-Frame ladder in the closed position as a means of access from the parapet wall to the roof of the main building.    Violation observed on or about April 26, 2018
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3326

1926.1053 B01

Serious Gravity 5 3 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:       a. 820 US Highway 9, Avenel, NJ - Wendy's  Employees engaged in commercial HVAC installation activities used a Werner 12-foot A-frame ladder as access from ground level to the roof that did not extend at least three feet above the landing surface.  Violation observed on or about April 26, 2018  b. 820 US Highway 9, Avenel, NJ - Wendy's  Employees engaged in commercial HVAC installation activities used a Werner 12-foot, A-frame ladder as access from the lower roof to the top of the parapet wall  that did not extend at least three feet above the landing surface.  Violation observed on or about April 26, 2018  c. 820 US Highway 9, Avenel, NJ - Wendy's  Employees engaged in commercial HVAC installation activities used a Werner 4-foot, A-frame ladder as access from the parapet wall to the roof that did not extend at least three feet above the landing surface.  Violation observed on or about April 26, 2018
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 3 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or next to the top step of a stepladder was used as a step:     a. 820 US Highway 9, Avenel, NJ - Wendy's    Employees engaged in commercial HVAC installation activities used the top step of a Werner 4-foot A-frame ladder as access from the parapet wall to the roof.    Violation observed on or about April 26, 2018