WOLFFORTH, TX —
OSHA Inspection: GUILLERMO MENDEZ ROOFING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of GUILLERMO MENDEZ ROOFING in 1404 KNIGHT AVE, WOLFFORTH, TX 79382 (NAICS 238160). OSHA activity number 343122271.
Where did this inspection happen?
- Establishment
- GUILLERMO MENDEZ ROOFING
- Site address
- 1404 KNIGHT AVE
- City
- WOLFFORTH
- State
- TX
- ZIP
- 79382
- Mailing
- 406 W 5TH, MULESHOE, TX 79347
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3326.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Employees were working on the third story roof of a residential home under construction without any visible means of fall protection, exposing employees to fall hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $3326
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed Employees were exposed to fall hazards while using a job made wooden ladder that was not set up at least three feet above the upper landing surface to access the third level of a residential home under construction.
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343122271.