Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JACOBI CARBONS, INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of JACOBI CARBONS, INC in 432 MCCORMICK BLVD, COLUMBUS, OH 43213 (NAICS 324199). OSHA activity number 343138715.

Watch Jacobi Carbons, INC — free Get an email when a new federal OSHA severe-injury report for Jacobi Carbons, INC is published. One employer, no account, unsubscribe in one click.
Establishment
JACOBI CARBONS, INC
Site address
432 MCCORMICK BLVD
City
COLUMBUS
State
OH
ZIP
43213
Mailing
432 MCCORMICK BLVD, COLUMBUS, OH 43213
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324199
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.22 A03

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $9054.00 · Current $5885.00 Reduced
29 CFR 1910.22(a)(3): (3) Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  a. In the CRISP Room, the work platform located near the Double Cone was not maintained free of hazards. On or about April 26, 2018, an employee was working on the work platform when a ball valve located on the Double Cone was opened, and hot oil was sprayed onto the employee, resulting in 3rd degree burns.
Recent events (2)
  • — I (S) $5885.1
  • — Z (S) $9054

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $4204.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.    a. At the workplace, the employer did not document the energy control procedures for servicing and maintenance of equipment such as, but not limited to, the Munson Machine and Mill 3.
Recent events (2)
  • — I (O) $4203.55
  • — Z (S) $6467

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343138715.