MANHEIM, PA —
OSHA Inspection: DUNCANNON INVESTMENT GROUP III
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DUNCANNON INVESTMENT GROUP III in 199 W STEIGEL ST, MANHEIM, PA 17545 (NAICS 335912). OSHA activity number 343146908.
Where did this inspection happen?
- Establishment
- DUNCANNON INVESTMENT GROUP III
- Site address
- 199 W STEIGEL ST
- City
- MANHEIM
- State
- PA
- ZIP
- 17545
- Mailing
- 199 W STEIGEL ST, MANHEIM, PA 17545
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335912
- Employees
- 17
- Ownership type
- A
Citations
13 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $425.00 · Current $425.00
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) 199 West Steigel Street Manheim, Pennsylvania - The employer did not certify Citation 1 Item 8a and Citation 1 Item 8b had been abated within 10 days of the abatement date, on or about January 11, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $425
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) Warehouse - Material was not kept clear of two exit routes in the warehouse, on or about May 9, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $2217
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) Warehouse - The employer does not ensure that employees working with corrosive materials wear eye protection, on or about May 9, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $3696
1910.141 G02
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials: (a) Warehouse - The employer did not prevent employees from drinking beverages in the battery recharging area near lead acid batteries that are being reconditioned, on or about May 9, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $5174
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2956.00 · Current $2600.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Warehouse - Employees handled, opened and refilled lead acid automotive batteries and were exposed to corrosive sulfuric acid. One of two eyewash stations provided for employee use did not have any fluid in it on or about May 10,2018 Employees working with chemicals such as but not limited to: sulfuric acid, did not have access to three eye wash stations that were either blocked by freight, missing fluid, or have not been inspected for two years on or about May 10, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2600
- — Z (S) $2956
1910.303 B01
- Issued
- Abate by
- Penalty
- Initial $2956.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) Warehouse - The employer did not ensure that the forklift battery re-charger cables were free of damage as several areas of the cables had exposed copper and others had attempted repairs with electrical tape, on or before May 9, 2018. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $2956
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $3354.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment were not installed and used in accordance with any instructions included in the listing or labeling: (a) Warehouse - Employees used a heat gun which was plugged into a re-locatable power tap (power strip). Re-locatable power strips are not intended to be used as a replacement for fixed wiring according to the listing and labeling (UL-1363) May 10, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3354
- — Z (S) $3696
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $2956.00 · Current $2600.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) Warehouse - The employer did not ensure that employees conduct visual inspection of flexible cords. A orange flexible cord used to provide power to a heat gun used by employees to remove decals from reconditioned batteries had multiple nicks and repairs covered by electrical tape, The cord was lying in wet sections of the floor on or about May 9, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2600
- — Z (S) $2956
1910.1018 E02
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1018(e)(2): Initial monitoring was not performed for each workplace, or work operation covered by 29 CFR 1910.1018 to accurately determine the airborne concentration of inorganic arsenic to which employees may be exposed: (a) Warehouse - The employer did not determine if employees handling lead batteries are exposed to arsenic at or above the action level, on or before May 10, 2018 Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — Z $0
- — I (S) $0
- — Z (S) $5174
1910.1025 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: (a) Warehouse - The employer did not determine if employees handling lead batteries are exposed to lead at or above the action level, on or before May 10, 2018 Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1018 K01
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1018(k)(1): All surfaces were not maintained as free as practicable of accumulations of inorganic arsenic: (a) Front Desk/Customer Service - Surfaces were not kept as free as practical from arsenic contamination, on or about May 10, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $5174
1910.1025 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: (a) Front Desk/ Customer Service - The surface of the front desk was contaminated with lead with a result of 1846 micrograms per 100 square centimeters on or about May 10, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit." (a) Warehouse - An exit door in the warehouse was not marked "EXIT", on or about May 10, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DUNCANNON INVESTMENT GROUP III
MANHEIM, PA—2019-04-09 00:00:00
DUNCANNON INVESTMENT GROUP III
View DUNCANNON INVESTMENT GROUP III's full OSHA safety record →
More inspections in this industry (NAICS 335912)
WOOSTER, OH—2026-06-10
SCHAEFFLER BATTERY TECHNOLOGIES LLC
RAYNHAM, MA—2026-06-03
ELECTROCHEM SOLUTIONS, INCORPORATED
KINGSTON, GA—2026-05-06
HSBMA LLC
VALDESE, NC—2026-04-16
160969 - SAFT AMERICA INC
GREENSBORO, NC—2026-04-14
160944 - SUNLIGHT BATTERIES USA INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343146908.