1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALLEGHENY CONTRACT FLOORING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALLEGHENY CONTRACT FLOORING INC. in HORIZON WAY, EVERETT, MA 02149 (NAICS 238330). OSHA activity number 343148797.

Watch Allegheny Contract Flooring INC. — free Get an email when a new federal OSHA severe-injury report for Allegheny Contract Flooring INC. is published. One employer, no account, unsubscribe in one click.
Site address
HORIZON WAY
City
EVERETT
State
MA
ZIP
02149
Mailing
36 HOLTON STREET, WINCHESTER, MA 01890
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238330
Employees
218
Ownership type
A

5 citations on file for this inspection.

1926.54 A

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6652.00 · Current $3000.00 Reduced
29 CFR 1926.54(a): Persons not trained and not qualified were assigned to install, adjust, and operate laser equipment:    a) Encore Casino, Tower, 5th floor, Room 509    On or about May 2, 2018, an employee using a laser in the tile setting process was not trained or qualified to operate laser equipment.     Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $3000
  • — Z (S) $6652

1926.54 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.54(b): Proof of qualification of the laser equipment operator were not available and in the possession of the operator at all times:    a) Encore Casino, Tower, 5th floor, Room 509    On or about May 2, 2018, an employee using a laser in the tile setting process did not have proof of qualifications for use of the laser level.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.54 C

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.54(c): Employees working in areas with a potential exposure direct or reflected laser light greater than 5 milliwatts were not provided with anti-laser eye protection devices as specified in subpart E of 29 CFR 1926:    a) Encore Casino, Tower, 5th floor, Room 509    On or about May 2, 2018, an employee using a laser in the tile setting process did not have adequate eye protection to prevent incidental exposure to the laser beam.     Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.54 D

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.54(d): Standard laser warning placards were not posted in areas in which lasers were used:    a) Encore Casino, Tower, 5th floor, Room 509    On or about May 2, 2018, an employee using a laser in the tile setting process did not have signs posted in the room, nor outside of the room, where the employee was using the laser.     Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.403 I02 I

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $6652.00 · Current $0.00 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:  a) Encore Casino, 6th Floor Tower, Room 617 and 619  On or about May 3, 2018, employees were exposed to live parts of electrical outlets that were used to charge powered pallet jacks used by the employer to move material. The electrical outlets were not covered, exposing the live parts of the outlet.   Abatement certification of this item is required in accordance with the requirements of 29 CFR 1903.19(c).