OSHA Inspection: PKF MARK III, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PKF MARK III, INC. in 1297 PROVIDENCE RD., SECANE, PA 19018 (NAICS 237310). OSHA activity number 343161329.

Watch PKF Mark III, INC. — free Get an email when a new federal OSHA severe-injury report for PKF Mark III, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PKF MARK III, INC.
Site address
1297 PROVIDENCE RD.
City
SECANE
State
PA
ZIP
19018
Mailing
P.O. BOX 390, NEWTOWN, PA 18940
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
150
Ownership type
A

2 citations on file for this inspection.

1926.701 B

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $6488.00 · Current $3893.00 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement:    a)1297 Providence Rd, Secane, PA  Employees were exposed to implement hazards in that the employer failed to guard horizontally protruding steel all-thread rods ( approximately 3/8 diameter, protruding approximately 1 foot), set in hardened concrete. This condition was observed on or about May 15, 2018.
Recent events (3)
  • — F (O) $3892.8
  • — C (S) $6488
  • — Z (S) $6488

1926.152 E04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $5407.00 · Current $0.00 Reduced
29 CFR 1926.152(e)(4): Units dispensing flammable or combustible liquids were not protected against collision damage:  a)  a) 1297 Providence Rd., Secane, PA 19018 - The employer did not protect a 500-gallon tank, which contained diesel fuel and was used to store and dispense diesel fuel, from collision damage, thus exposing employees to fire hazards.  This condition was observed on or about May 15, 2018.
Recent events (3)
  • — F (S) $0
  • — C (S) $5407
  • — Z (S) $5407

View PKF MARK III, INC.'s full OSHA safety record →