Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POLYMER SOLUTIONS GROUP FUNCTIONAL MATERIALS LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of POLYMER SOLUTIONS GROUP FUNCTIONAL MATERIALS LLC in 2200 ABUTMENT RD, DALTON, GA 30721 (NAICS 325998). OSHA activity number 343178620.

Watch Polymer Solutions Group Functional Materials LLC — free Get an email when a new federal OSHA severe-injury report for Polymer Solutions Group Functional Materials LLC is published. One employer, no account, unsubscribe in one click.
Site address
2200 ABUTMENT RD
City
DALTON
State
GA
ZIP
30721
Mailing
P.O BOX 1087, ROME, GA 30162
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
500
Ownership type
A

2 citations on file for this inspection.

1910.151 C

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $12934.00 · Current $7760.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Rail Yard: On or about 5/3/18, and at times prior, the employer exposed employees to chemical hazards, in that plumbed eyewash stations for quick drenching of the eyes were not provided to employees while working with corrosive hazardous material such as 50% Sodium Hydroxide (NaOH) or acetic acid.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.134 F01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   (a) Rail Yard- On or about 5/3/18, and at times prior, the employer exposed employees to upper respiratory irritation, in that FIT test were not provided to employees prior to wearing 3M tight fitting half-face respirators.