CLEBURNE, TX —
OSHA Inspection: DPC INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DPC INDUSTRIES, INC. in 601 W. INDUSTRIAL BLVD., CLEBURNE, TX 76033 (NAICS 221310). OSHA activity number 343179636.
Where did this inspection happen?
- Establishment
- DPC INDUSTRIES, INC.
- Site address
- 601 W. INDUSTRIAL BLVD.
- City
- CLEBURNE
- State
- TX
- ZIP
- 76033
- Mailing
- 601 W. INDUSTRIAL BLVD., CLEBURNE, TX 76033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221310
- Employees
- 30
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.28 B04 I
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(4)(i): The employer must ensure that each employee on a dockboard is protected from falling 4 feet (1.2 m) or more to a lower level by a guardrail system or handrails. At a facility located at 601 W. Industrial Blvd., Cleburne, Texas: at the tank farm dock area, the employer did not ensure employees were protected from falls by placing rails/chains across the dock openings exposing employees to a fall hazard of 4 feet to the ground below.
Recent events (2)
- — I (O) $2000
- — Z (S) $5174
1910.119 J04 I
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer is not conducting inspections and tests of process equipment. a. The employer is not conducting inspection and testing of piping systems in accordance with its mechanical integrity program. Based on the inspection and testing documents, DCP was operating piping that was below their thickness minimum; thereby requiring more frequent inspections. The inspections had not been performed in within the required time-frame as defined in their mechanical integrity program. Piping Circuit 76CL2I109 1. TML 150.02 Tmin.: .170 Tested value .162 Next inspection date: 1/29/2012 2. TML 150.01 Tmin.: .170 Tested value .168 Next inspection date: 1/29/2012 3. TML 149.03 Tmin.: .170 Tested value .122 Next inspection date: 1/20/2015 b. No short or long-term corrosion rates were established for: Piping Circuit 76CL2I118
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.134 H03 I B
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.134(h)(3)(i)(B): The employer did not inspect all respirators maintained for use in emergency situations at least monthly, and in accordance with the manufacturer's recommendations; and shall be checked for proper function before and after each use. On or about May 24, 2018, respirators maintained for use by employees in emergency situations were not inspected at least monthly. Four Self-Contained Breathing Apparatus (SCBA) respirators located on the floor in the cylinder production and storage area had not inspected monthly.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. Note: Eyewash stations installation and the maintenance must comply with ANSI/ISEA Z358 standards to be suitable. At a facility located at 601 W. Industrial Blvd., Cleburne, Texas: at the tank farm area, the employer did not ensure eyewash stations were inspected, tested and ready available for employees working with hazardous material such as but not limited to chlorine, sulfur and glycol. The employees were exposed to eye and skin irritation.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1910.119 J02
- Issued
- Abate by
- Penalty
- Initial $726.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employers did not develop and implement written procedures to maintain the ongoing integrity of the process equipment. The employer did not effectively implement its mechanical integrity program. The employers mechanical integrity procedure ENG 00082 indicates that Vitality Testing of all sensors will be completed every month; when in fact the employer is conducting this testing on a bi-annual basis.
Recent events (2)
- — I (O) $500
- — Z (O) $726
More inspections at DPC INDUSTRIES, INC.
HUDSON, CO—2013-07-31 00:00:00
DPC INDUSTRIES, INC.
CLEBURNE, TX—1995-01-06 00:00:00
DPC INDUSTRIES INC.
SWEETWATER, TX—1993-10-13 00:00:00
DPC INDUSTRIES, INC.
View DPC INDUSTRIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 221310)
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
ROYAL OAK, MI—2026-07-15
SOUTHEASTERN OAKLAND COUNTY WATER AUTHORITY
CARTHAGE, TN—2026-07-10
SMITH UTILITY DISTRICT WATER TREATMENT PLANT
PATERSON, WA—2026-07-10
WA317992032 - COLUMBIA WATER & POWER DISTRICT
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343179636.