OSHA Inspection: DPC INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DPC INDUSTRIES, INC. in 601 W. INDUSTRIAL BLVD., CLEBURNE, TX 76033 (NAICS 221310). OSHA activity number 343179636.

Watch DPC Industries, INC. — free Get an email when a new federal OSHA severe-injury report for DPC Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 W. INDUSTRIAL BLVD.
City
CLEBURNE
State
TX
ZIP
76033
Mailing
601 W. INDUSTRIAL BLVD., CLEBURNE, TX 76033
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221310
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.28 B04 I

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2000.00 Reduced
29 CFR 1910.28(b)(4)(i): The employer must ensure that each employee on a dockboard is protected from falling 4 feet (1.2 m) or more to a lower level by a guardrail system or handrails.       At a facility located at 601 W. Industrial Blvd., Cleburne, Texas: at the tank farm dock area, the employer did not ensure employees were protected from falls by placing rails/chains across the dock openings exposing employees to a fall hazard of 4 feet to the ground below.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $5174

1910.119 J04 I

Deleted Serious Gravity 10 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $0.00 Reduced
29 CFR 1910.119(j)(4)(i): The employer is not conducting inspections and tests of process equipment.     a.  The employer is not conducting inspection and testing of piping systems in accordance with its mechanical integrity program.   Based on the inspection and testing documents, DCP was operating piping that was below their thickness minimum; thereby requiring more frequent inspections. The inspections had not been performed in within the required time-frame as defined in their mechanical integrity program.  Piping Circuit 76CL2I109  1.     TML 150.02 Tmin.: .170 Tested value .162  Next inspection date: 1/29/2012  2.     TML 150.01 Tmin.: .170 Tested value .168  Next inspection date: 1/29/2012  3.     TML 149.03 Tmin.: .170 Tested value .122  Next inspection date: 1/20/2015  b.     No short or long-term corrosion rates were established for:  Piping Circuit 76CL2I118
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.134 H03 I B

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $0.00 Reduced
29 CFR 1910.134(h)(3)(i)(B): The employer did not inspect all respirators maintained for use in emergency situations at least monthly, and in accordance with the manufacturer's recommendations; and shall be checked for proper function before and after each use.   On or about May 24, 2018, respirators maintained for use by employees in emergency situations were not inspected at least monthly.  Four Self-Contained Breathing Apparatus (SCBA) respirators located on the floor in the cylinder production and storage area had not inspected monthly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.151 C

Deleted Serious Gravity 1 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $0.00 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  Note: Eyewash stations installation and the maintenance must comply with ANSI/ISEA Z358 standards to be suitable.   At a facility located at 601 W. Industrial Blvd., Cleburne, Texas: at the tank farm area, the employer did not ensure eyewash stations were inspected, tested and ready available for employees working with hazardous material such as but not limited to chlorine, sulfur and glycol.  The employees were exposed to eye and skin irritation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1910.119 J02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $726.00 · Current $500.00 Reduced
29 CFR 1910.119(j)(2): The employers did not develop and implement written procedures to maintain the ongoing integrity of the process equipment.       The employer did not effectively implement its mechanical integrity program. The employers mechanical integrity procedure ENG 00082 indicates that Vitality Testing of all sensors will be completed every month; when in fact the employer is conducting this testing on a bi-annual basis.
Recent events (2)
  • — I (O) $500
  • — Z (O) $726

View DPC INDUSTRIES, INC.'s full OSHA safety record →