Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECONOMY POOLS OF FLORIDA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ECONOMY POOLS OF FLORIDA, INC. in 781 US 41 BYPASS S., VENICE, FL 34285 (NAICS 453998). OSHA activity number 343188496.

Watch Economy Pools OF Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Economy Pools OF Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
781 US 41 BYPASS S.
City
VENICE
State
FL
ZIP
34285
Mailing
3930 TAMPA RD., OLDSMAR, FL 34677
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
13
Ownership type
A

9 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1940.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition.  a)  On or about May 29, 2018, at the retail store, employees were exposed to trip and fall hazards from an uneven working surface from damaged rugged carpet and black mats in the walkway.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2587.00 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) On or about May 29, 2018, employees dispensing corrosive chemicals such as, but not limited to, Sodium Hypochlorite 10.5% into secondary containers were not wearing goggles or a face shield, exposing to eye injuries.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.138 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1940.00 Reduced
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:  (a) On or about May 29, 2018, at the chemical dispensing area, employees were exposed to chemical burns when dispensing Sodium Hypochlorite solution (10.5%) into secondary containers without hand protection, such as but not limited to impervious gloves.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2587.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) On or about May 29, 2018, at the chemical dispensing area, the employer did not have available an eye wash station for employees dispensing Sodium Hypochlorite solution (10.5%) into secondary containers, exposing employees to chemical burns.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2587.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) On or about May 29, 2018, at the hallway near the office, the wall mounted open electrical panel had circuit-breaker slots #19 and 22 not effectively closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2587.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) On or about May 29, 2018, at the worksite, the employer did not have a Hazard Communication Program. Employees were exposed to the hazards of corrosive chemicals such as, but not limited to Sodium Hypochlorite solution (10.5%).
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.303 B02

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) On or about May 29, 2018, in the office/storage room, the power outlet box was not properly secured onto the wall opening, exposing employees to electrical hazards.  (b) On or about May 29, 2018, behind the sales counter, the power outlet box was not properly secured onto the wall opening, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) On or about May 29, 2018, at the office/store room in the rear of the retail area, employees were exposed to an electrical and fire hazard from the electrical cabinet not being marked or labeled to indicate purpose of breakers.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or about May 29, 2018, at the wall below product display, employees were exposed to burns from a metal outlet box that had its faceplate hanging by its electrical wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343188496.