DOWNERS GROVE, IL —
OSHA Inspection: JF WRECKING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JF WRECKING INC. in 28 ODEN AVE., DOWNERS GROVE, IL 60515 (NAICS 238910). OSHA activity number 343196739.
Where did this inspection happen?
- Establishment
- JF WRECKING INC.
- Site address
- 28 ODEN AVE.
- City
- DOWNERS GROVE
- State
- IL
- ZIP
- 60515
- Mailing
- 2508 LIVE OAK DR., CREST HILL, IL 60403
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 D01
- Issued
- Abate by
- Penalty
- Initial $311.00 · Current $311.00
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required JF Wrecking, Inc., failed to submit documents to OSHA verifying that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 1 1 08/10/2018 1 5 08/10/2018 In accordance with 29 CFR 1903.19(d), abatement documentation is required for this violation.
Recent events (1)
- — Z (O) $311
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1903.19(c)(1): The employer failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: JF Wrecking, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 1 2 08/10/2018 1 3 08/10/2018 1 4 08/24/2018 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $0
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3880.00
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. On or about June 1, 2018, employees working from a frame scaffold were not provided with enough planks to safely plank the entire work surface, exposing employees to a fall hazard of approximately 19 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $3880
1926.451 C01 II
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1926.451(c)(1)(ii): The top guy, tie, or brace of completed scaffolds were placed further than the 4:1 height from the top. Such guys, ties and/or braces were not installed at each end of the scaffold and/or at horizontal intervals not to exceed 30 feet (9.1 m): On or about June 1, 2018, employees were exposed to fall hazards while working from a frame scaffold with a ratio of 5:1 that was not protected from scaffold collapse by guying or tying the scaffold. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $2772
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1663.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. On or about June 1, 2018, employees working from a frame scaffold were not provided with a safe means of access, exposing employees to a fall hazard and other associated other injuries. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1663
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2772.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. On or about June 1, 2018, employees were not competent to safely erect a fabricated metal frame scaffold, exposing the employees to the hazards associated with a scaffold collapse and fall hazards. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $2772
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3880.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. On or about June 1, 2018, employees working from a frame scaffold were not protected from fall hazards, exposing employees to a falls of approximately 19 feet. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
- — Z (S) $3880
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343196739.