OSHA Inspection: FOX ELECTRIC 1 LTD

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FOX ELECTRIC 1 LTD in 3100 NORTHSIDE BLVD, RICHARDSON, TX 75080 (NAICS 238210). OSHA activity number 343240040.

Watch FOX Electric 1 LTD — free Get an email when a new federal OSHA severe-injury report for FOX Electric 1 LTD is published. One employer, no account, unsubscribe in one click.
Establishment
FOX ELECTRIC 1 LTD
Site address
3100 NORTHSIDE BLVD
City
RICHARDSON
State
TX
ZIP
75080
Mailing
PO BOX 13338, ARLINGTON, TX 76094
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
300
Ownership type
A

1 citation on file for this inspection.

1926.403 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $12934.00 · Current $12934.00
29 CFR 1926.403(b)(1): The employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:   In the alternative:  29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  (a) This violation occurred on or before May 22, 2018, at the job site located at 3100 Northside Blvd, Richardson, TX 75080, at the Northside II Apartment Complex, building #6, on the fourth floor, where employees working and installing electrical wires to the Schindler model 3300 simplex elevators exposed to an electrical hazard.  (b) This violation occurred on or about May 22, 2018, at the job site located at 3100 Northside Blvd, Richardson, TX 75080, at the Northside II Apartment Complex, building #6, on the fourth floor, on the Schindler model 3300 simplex elevator, where employees working, testing, adjusting, balancing, and connecting auxiliary wires were exposed to an electrical hazard.
Recent events (1)
  • — Z (S) $12934

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343240040.