Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JYI MASONRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JYI MASONRY in 1100 UNIVERSITY DRIVE EAST, COLLEGE STATION, TX 77840 (NAICS 238140). OSHA activity number 343248159.

Watch JYI Masonry — free Get an email when a new federal OSHA severe-injury report for JYI Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
JYI MASONRY
Site address
1100 UNIVERSITY DRIVE EAST
City
COLLEGE STATION
State
TX
ZIP
77840
Mailing
3801 WOODY LANE, BRYAN, TX 77803
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $900.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.    On or about 21 June 2018, and at times prior thereto, four masons were performing masonry work on a scaffold without the use of hard hats, exposing the masons to the hazard of being struck by falling tools, materials, and debris.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1663

1926.451 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1100.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii).    On or about 21 June 2018, and at times prior thereto, a mason was performing masonry work on a scaffold at the second tier in which the platform was not fully planked from front to back, exposing the mason to the hazard of falling approximately 11 feet 7 inches to the ground below.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2217

1926.451 C02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1100.00 Reduced
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.    On or about 21 June 2018, and at times prior thereto, four masons accessed a tubular-welded frame scaffold up to the third tier without the feet having a mud sill or similar solid surface for supporting the scaffold and load, exposing the masons to the hazard of falling approximately 18 feet to the ground below from the scaffold tipping over or displacing.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2217

1926.451 C03

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1100.00 Reduced
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement.    On or about 21 June 2018, and at times prior thereto, four masons accessed a tubular-welded frame scaffold up to the third tier without cross-braces being in place at the 1st and 2nd levels of one section, exposing the masons to the hazard of falling approximately 18 feet to the ground below from the scaffold swaying or displacing.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2217

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1100.00 Reduced
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access.    On or about 21 June 2018, and at times prior thereto, four masons accessed the three tier tubular-welded frame scaffold without the use of a ladder, exposing the masons to the hazard of falling approximately 18 feet to the ground below.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2217

1926.451 G04 I

Repeat Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4435.00 · Current $2200.00 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.    On or about 21 June 2018, and at times prior thereto, four masons were performing masonry work on a scaffold at the third tier without the use of fall protection, exposing the masons to the hazard of falling approximately 18 feet to the ground below.    JYI Masonry was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(4)(I), which was contained in OSHA inspection number 1289193, citation number 01, item number 001 and was affirmed as a final order on 03/30/2018, with respect to a workplace located at 903 William D. Fitch Pkwy., College Station, TX 77845.
Recent events (2)
  • — I (R) $2200
  • — Z (R) $4435