On , OSHA opened a planned safety inspection of SANTOS & BROTHERS MASONRY, LLC. in 175 NEW EGYPT ROAD, LAKEWOOD, NJ 08701 (NAICS 238140). OSHA activity number 343251450.

Watch Santos & Brothers Masonry, LLC. — free Get an email when a new federal OSHA severe-injury report for Santos & Brothers Masonry, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
175 NEW EGYPT ROAD
City
LAKEWOOD
State
NJ
ZIP
08701
Mailing
27 SEMINOLE DRIVE, LAKEWOOD, NJ 08701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.416 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3049.00 · Current $3049.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a- 175 New Egypt Road, Lakewood NJ: On or about 06/25/18, company employees were using a flexible extension cord to power their worksite equipment.  This cord was visibly damaged and exposed the employees to electrical hazards.    NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $3049

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4268.00 · Current $4268.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a- 175 New Egypt Road, Lakewood NJ: On or about 06/25/18, a company employee was exposed to fall hazards in excess of 19 feet to the ground surface below when working from a supported scaffold that was not fully planked between the front uprights.     NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4268

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4268.00 · Current $4268.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a- 175 New Egypt Road, Lakewood NJ: On or about 06/25/18, company employees were exposed to fall hazards in excess of 14 feet to the ground surface below when accessing and egressing the working levels of a supported scaffold using the scaffold's crossbraces.     NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4268

1926.451 E06 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4268.00 · Current $4268.00
29 CFR 1926.451(e)(6)(vi): 1926.451(e)(6)(vi):  Integral prefabricated scaffold access frames being used for access had a spacing greater than 16 3/4 inches.  a- 175 New Egypt Road, Lakewood NJ: On or about 06/25/18, company employees were exposed to fall hazards in excess of 14 feet to the ground surface below when accessing and egressing the working levels of a supported scaffold using openings in the scaffold's end frames which had spaces greater than 16 3/4 inches.      NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4268

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4268.00 · Current $4268.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a- 175 New Egypt Road, Lakewood NJ: On or about 06/25/18, company employees were exposed to fall hazards in excess of 14 feet to the ground surface below when working from: a supported scaffold that was missing a mid-rail and guard rails for its unprotected frame openings, two boards that bridged from the supported scaffold onto a residential structure's entrance roof that were not supplied with any guardrails, and side brackets that were not supplied with end stops.     NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4268