Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OHIO ELECTRO-POLISHING CO. INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of OHIO ELECTRO-POLISHING CO. INC. in 15085 MAIN ST., VENEDOCIA, OH 45894 (NAICS 332813). OSHA activity number 343263497.

Watch Ohio Electro-Polishing CO. INC. — free Get an email when a new federal OSHA severe-injury report for Ohio Electro-Polishing CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
15085 MAIN ST.
City
VENEDOCIA
State
OH
ZIP
45894
Mailing
15085 MAIN ST., VENEDOCIA, OH 45894
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
2
Ownership type
A

3 citations on file for this inspection.

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  1.)    On or about July 12, 2018 the employer did not certify that a hazard assessment was performed to address the chemical and physical hazards found in the workplace.  The employer did not have written certification that long sleeved gloves that are used to reach into the plating vessels to retrieve parts are designed for the hazards.
Recent events (1)
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2612Z100

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:     1.) On or about July 12, 2018, the employer failed to conduct exposure monitoring to determine employees exposure to various metals and acids, such as, but not limited to, zinc and hydrochloric acid while working on electroplating lines.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2612Z100

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      1.) On or about July 12, 2018,  The employer failed to implement the elements of a written hazard communication program.  Employees were exposed to hazards from Metals and acids including but not limited to zinc and hydrochloric acid.
Recent events (1)
  • — Z (O) $0