OSHA Inspection: SETTLERS HOSPITALITY GROUP, LLC AKA MILL MARKET

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SETTLERS HOSPITALITY GROUP, LLC AKA MILL MARKET in 8 SILK MILL DRIVE, HAWLEY, PA 18428 (NAICS 311812). OSHA activity number 343266805.

Watch Settlers Hospitality Group, LLC AKA Mill Market — free Get an email when a new federal OSHA severe-injury report for Settlers Hospitality Group, LLC AKA Mill Market is published. One employer, no account, unsubscribe in one click.
Site address
8 SILK MILL DRIVE
City
HAWLEY
State
PA
ZIP
18428
Mailing
8 SILK MILL DRIVE, HAWLEY, PA 18428
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
13
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $4434.00 · Current $3000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion, burn, and penetrating trauma hazards.    a) Bakery, 8 Silk Mill Drive, Hawley, PA - Employees toasted pastries with a Mag-Torch Model MT 535 Torch Head with a broken valve (could not be turned off) and were exposed to explosion, burn and penetrating trauma hazards. An employee received burns when excess propane from the cylinder ignited and created a fireball, on or about June 16, 2018.    In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4434

1910.303 B01 I

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1000.00 Reduced
29 CFR 1910.303(b)(1)(i) - Electric equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the installed electrical outlets were not suitable for use within six (6) foot of a sink or within a kitchen exposing employees to contact with an electrical current and fire hazards:    a) South Corner, Bakery, 8 Silk Mill Drive, Hawley, PA - A paired set of duplex receptacles (located three (3) foot northwest of the employee hand sink) used by employees for preparing bakery products with electrical equipment, such as but not limited to a Chefman Model RJ23-SM Electric Griddle, a Spring USA Model SM-181R MAX Induction Range, and a a Globe Food Equipment Model PF10E Countertop Electric Fryer lacked ground-fault circuit interrupter (GFCI) protection exposing employees to contact with an electrical current and fire hazards, as observed on or about June 29, 2018.    In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2217

1910.303 B01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  a) North Corner, Bakery, 8 Silk Mill Drive, Hawley, PA - The top cover of the Linkrich Model 50L Spiral Mixer directly southeast of the stainless steel two-compartment sink was damaged with two (2) holes that allowed flour dust and water to coat the inner electrical connections exposing employees to contact with an electrical current and fire hazards, as observed on or about June 29, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B04 II B

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  a) South Corner, Bakery, 8 Silk Mill Drive, Hawley, PA - Employees prepared baked products at the same time with combinations of a Chefman Model RJ23-SM Electric Griddle operated at 1200 watts (10 amps), a Spring USA Model SM-181R MAX Induction Range at 1800 watts (15 amps), and/or a Globe Food Equipment Model PF10E Countertop Electric Fryer at 1700 watts (14.2 amps) powered from a paired set of duplex receptacles through a 20 amp Eaton Model BR120 Circuit Breaker which exceeded the maximum capacity of 16 amps found in Table S-4. Employees were exposed to contact with an electrical current and fire hazards, as observed on or about June 29, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.176(b): Storage of material created a hazard:  a) Bakery, 8 Silk Mill Drive, Hawley, PA - Six (6) wall mounted metal shelves were not securely fastened to the wall, level, or plumb and items stored upon the shelves were not secured against sliding or falling exposing employees to struck-by hazards, as observed on or about June 29, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343266805.