Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JEFF SEESE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JEFF SEESE in 3484 DEERFIELD AVE, NORTH LAWRENCE, OH 44666 (NAICS 238160). OSHA activity number 343267241.

Watch Jeff Seese — free Get an email when a new federal OSHA severe-injury report for Jeff Seese is published. One employer, no account, unsubscribe in one click.
Establishment
JEFF SEESE
Site address
3484 DEERFIELD AVE
City
NORTH LAWRENCE
State
OH
ZIP
44666
Mailing
3484 DEERFIELD AVE, NORTH LAWRENCE, OH 44666
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $0.00 Reduced
29 CFR 1926.102(a)(1): 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   On or about June 29, 2018, employees that were stripping shingles were not utilizing eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2217

1926.451 E01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $0.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  On or about June 29, 2018, employees accessed the platform of a ladder jack scaffold, which was on the climbing side, by climbing up the support ladders. The front face of the platform was more than 2 feet above the portion of the ladder immediately below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

1926.1053 B04

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   On or about June 29, 2018, employees were accessing the roof of a garage by using a stepladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On or about June 29, 2018, employees utilizing a ladder jack scaffold at a height of approximately 21 feet were not protected from falling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2772

1926.501 B13

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a. On or about June 29, 2018, employees performing roofing activities from the roof of a residential home with a pitch of approximately 9:12 were not protected from falling approximately 21 feet to the ground below.     b. On or about June 29, 2018, employees performing roofing activities from the roof of a garage with a pitch of approximately 6:12 were not protected from falling approximately 7.8 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0