WESTON, WI —
OSHA Inspection: WOODSON YMCA ASSOCIATION, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of WOODSON YMCA ASSOCIATION, INC. in 3402 HOWLAND AVE, WESTON, WI 54476 (NAICS 713940). OSHA activity number 343282208.
Where did this inspection happen?
- Establishment
- WOODSON YMCA ASSOCIATION, INC.
- Site address
- 3402 HOWLAND AVE
- City
- WESTON
- State
- WI
- ZIP
- 54476
- Mailing
- 3402 HOWLAND AVE, WESTON, WI 54476
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713940
- Employees
- 131
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $12934.00 · Current $12934.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 7/9/2018, Employer had not established an energy control program for their employees which contributed to the electrocution death of the groundskeeper.
Recent events (2)
- — I (S) $12934
- — Z (S) $12934
1910.332 B02
- Issued
- Abate by
- Penalty
- Initial $12934.00 · Current $12934.00
General-duty citation text
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety: a) On or about 7/6/2018, Employee which did not have electrical training was working on light fixture wiring and was electrocuted.
Recent events (2)
- — I (S) $12934
- — Z (S) $12934
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1036.00 · Current $1036.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about 7/9/2018, Employer had not developed a written hazard communication program for their employees training and use creating a potential chemical exposure hazard.
Recent events (2)
- — I (O) $1036
- — Z (O) $1036
More inspections in this industry (NAICS 713940)
LAS VEGAS, NV—2026-07-09
CENTENNIAL MMA, LLC
REDONDO BEACH, CA—2026-07-07
CITY OF REDONDO BEACH, COMMUNITY SERVICES DEPARTMENT
BATH, NY—2026-06-30
PROJECT IRON GYM LLC
OLYMPIA, WA—2026-06-24
WA317991789 - EVERGREEN SPORTSMAN CLUB INC
UNION CITY, NJ—2026-06-16
BRUCE D. WALTER RECREATION CENTER
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343282208.