Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIHOUSE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIHOUSE LLC in 1207 6TH STREET, NE, WASHINGTON, DC 20002 (NAICS 238320). OSHA activity number 343291308.

Watch Dihouse LLC — free Get an email when a new federal OSHA severe-injury report for Dihouse LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DIHOUSE LLC
Site address
1207 6TH STREET, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
1629 K STREET, NW SUITE 300, WASHINGTON, DC 20006
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3880.00 · Current $2000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) Roof Level - An employee was painting while standing near the edge of roof and exposed to a 21 foot fall hazard, on or about 07/11/2018.    No abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) Exterior Front of Building - An employee used a ladder that only extended 24 inches above a roof landing that was 21 feet above a concrete sidewalk, on or about 07/11/2018.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).