COLORADO SPRINGS, CO —
OSHA Inspection: POTESTIO BROTHERS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of POTESTIO BROTHERS, INC. in 7380 SPACE VILLAGE AVE, COLORADO SPRINGS, CO 80929 (NAICS 423820). OSHA activity number 343294583.
Where did this inspection happen?
- Establishment
- POTESTIO BROTHERS, INC.
- Site address
- 7380 SPACE VILLAGE AVE
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80929
- Mailing
- 7380 SPACE VILLAGE AVE, COLORADO SPRINGS, CO 80929
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423820
- Employees
- 17
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7760.00 · Current $4656.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards which were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards associated with delivery of compressed air through PVC pipe: a) On or about June 30, 2018, and at times prior, employees were exposed to struck-by hazards when a portion of schedule 80 PVC piping burst while delivering compressed air at 75 to 120 psi to the shop area. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $4656
- — Z (S) $7760
1910.215 B09
- Issued
- Penalty
- Initial $3298.00 · Current $1900.00 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about July 10, 2018, and at times prior, the employer exposed employees in the shop area to struck-by hazards due to the DeWalt Heavy Duty 8" bench grinder tongue guard exceeding one fourth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1900
- — Z (S) $3298
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1444.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) On or about July 10, 2018, and at times prior, employees were exposed to struck by hazards in that the oxygen, acetylene and nitrogen cylinders, located in the shop area, were not secured in order to prevent tipping or damage. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1444
- — Z (S) $3880
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) On or about July 10, 2018, and at times prior, employees were exposed to fire and explosion hazards in that the employer did not store the oxygen cylinder 20 feet away from the acetylene cylinder. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about July 10, 2018, and at times prior, the employer did not maintain a clear distance of three feet in front of two circuit breaker panels, located in the main shop and in the storage building, in order to provide access for emergency maintenance. Abatement Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: a) On or about July 10, 2018, and at times prior, employees were exposed to hazardous chemicals in that the following containers, located in the shop area, were not labeled. 1) Spray bottle containing engine degreaser. 2) Water bottle containing an unknown substance, possibly coolant. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a) On or about July 10, 2018, and at times prior, the employer did not train employees on the new label elements, signal words and safety data sheets format that was required to be completed by December 1, 2013. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423820)
BEACH, ND—2026-07-09
NORED, INC.
BOWMAN, ND—2026-07-08
NORED, INC.
ELGIN, ND—2026-07-08
NORED, INC.
LEMMON, SD—2026-07-08
NORED, INC.
REDDING, CA—2026-07-02
TRACTOR SUPPLY CO
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.