Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARR EXCAVATING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARR EXCAVATING LLC in 6633 LEESTONE AVENUE, CANTON, OH 44721 (NAICS 238190). OSHA activity number 343297537.

Watch Carr Excavating LLC — free Get an email when a new federal OSHA severe-injury report for Carr Excavating LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CARR EXCAVATING LLC
Site address
6633 LEESTONE AVENUE
City
CANTON
State
OH
ZIP
44721
Mailing
6179 PILOT KNOBB AVENUE, LOUISVILLE, OH 44641
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2328.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    On or about July 12, 2018, the employer failed to provide a safe means of egress in an approximately 6.8 foot deep excavation as to require no more than 25 feet lateral travel for employees who were working to check the grating while the employer was digging a foundation for a new home.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1926.651 E

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(e): Employee was not prohibited to be underneath loads handled by lifting or digging equipment:  On or about July 12, 2018, the employer failed to prohibit employees from working underneath loads handled by digging equipment. Employees were exposed when they entered an approximately 6.8 foot deep excavation to check the grating while the employer was digging a foundation for a new home by pulling buckets of dirt and rocks with an excavator over the employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:    On or about July 12, 2018, the employer failed to ensure that an inspection of the excavations were conducted by a competent person. Employees were exposed to cave-in hazards when they entered an approximately 6.8 foot deep excavation to check the grating while the employer was digging a foundation for a new home.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):    On or about July 12, 2018, the employer failed to protect employees from cave-ins when they were working in an approximately 6.8 feet deep excavation to check the grating while the employer was digging a foundation for a new home.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343297537.