Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION PUMP & VALVE II, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION PUMP & VALVE II, INC. in 404 WESLEY STREET, LAKE CHARLES, LA 70606 (NAICS 213112). OSHA activity number 343308474.

Watch Precision Pump & Valve II, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Pump & Valve II, INC. is published. One employer, no account, unsubscribe in one click.
Site address
404 WESLEY STREET
City
LAKE CHARLES
State
LA
ZIP
70606
Mailing
406 WESLEY RD., LAKE CHARLES, LA 70606
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3326.00 · Current $1996.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    On or about July 17, 2018 at Precision Pump & Valve II, Inc  the employer failed to ensure that the eyewash station was made readily available to employees who use chemicals such as but not limited to: Premier Solvent.
Recent events (2)
  • — I (S) $1995.6
  • — Z (S) $3326

1910.178 L01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2328.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about July 17, 2018 at Precision Pump & Valve II, Inc, the employer failed to ensure that forklift operators were competent to operate the forklift. The employee used the forklift in order to load freight onto a truck.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.243 C01 II A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $0.00 Reduced
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) on portable abrasive wheel(s) were not mounted so as to maintain proper alignment with the wheel:  On or about July 17, 2018 at Precision Pump & Valve II, Inc. the employer failed to ensure that a DeWalt angle grinder was used with the guard while grinding metal parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1910.305 G01 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $311.00 · Current $187.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): Flexible cords were attached to building surfaces.       On or about July 17, 2018 at Precision Pump & Valve II, Inc., the employer allowed employees to utilize an extension cord as a power source for a 1000 lb. chain hoist. The chain hoist was used to move valves.
Recent events (2)
  • — I (O) $186.6
  • — Z (O) $311

View PRECISION PUMP & VALVE II, INC.'s full OSHA safety record →