KINGFISHER, OK —
OSHA Inspection: DEVON ENERGY PRODUCTION COMPANY, L.P.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEVON ENERGY PRODUCTION COMPANY, L.P. in 254 N 2740, KINGFISHER, OK 73750 (NAICS 213112). OSHA activity number 343319729.
Where did this inspection happen?
- Establishment
- DEVON ENERGY PRODUCTION COMPANY, L.P.
- Site address
- 254 N 2740
- City
- KINGFISHER
- State
- OK
- ZIP
- 73750
- Mailing
- 333 W. SHERIDAN AVE, OKLAHOMA CITY, OK 73102
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $11641.00 · Current $8000.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. On or about July 18, 2018 at a salt water disposal facility in Kingfisher, Oklahoma, employees were exposed to severe burns during an operation to break up sludge in a storage tank.
Recent events (2)
- — I (S) $8000
- — Z (S) $11641
1910.307 C
- Issued
- Abate by
- Penalty
- Initial $11641.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location. This violation occurred on July 18, 2018, a bonding clamp with uninsulated wire contacts was connected to the frame of a vacuum trailer within three feet of a vent line, which constituted a Class I, Division 2 location exposing employees to fire/explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $11641
1910.307 G02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $8000.00
General-duty citation text
29 CFR 1910.307(g)(2)(i): Locations were not classified depending on the properties of the flammable vapors, liquids, or gases that may be present and the likelihood that a flammable or combustible concentration or quantity is present. This violation occurred on or about July 18, 2018, at the Devon Safari Saltwater Disposal Well site, the area below the unloading pumps, the trench, is in an area that had not been documented properly as Class 1, Division 1.
Recent events (2)
- — I (S) $8000
- — Z (S) $0
More inspections at DEVON ENERGY PRODUCTION COMPANY, L.P.
WRIGHT, WY—2012-03-28 00:00:00
DEVON ENERGY PRODUCTION COMPANY L.P.
View DEVON ENERGY PRODUCTION COMPANY, L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
COLLBRAN, CO—2026-07-14
LARAMIE ENERGY
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source