SCHILLER PARK, IL —
OSHA Inspection: PRECISION STAMPING PRODUCTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRECISION STAMPING PRODUCTS, INC. in 4848 NORTH RIVER ROAD, SCHILLER PARK, IL 60176 (NAICS 332116). OSHA activity number 343336004.
Where did this inspection happen?
- Establishment
- PRECISION STAMPING PRODUCTS, INC.
- Site address
- 4848 NORTH RIVER ROAD
- City
- SCHILLER PARK
- State
- IL
- ZIP
- 60176
- Mailing
- 4848 NORTH RIVER ROAD, SCHILLER PARK, IL 60176
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $5174.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Production Area - On or about July 19, 2018, the employer did not ensure employees performing the task of adjusting and aligning the piece of roll fed material, fed from the Sesco Feeder, model #12-1015, serial #19871, were trained as an authorized employees to acquire the knowledge and skills needed for the safe application, usage, and removal of the energy controls.
Recent events (2)
- — I (S) $3000
- — Z (S) $5174
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d): 29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) covered the following elements, however, the actions were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6): a) Production Area - On or about July 19, 2018, an employee was exposed to machine hazards associated with moving parts while aligning the piece of roll fed material from the Sesco Feeder, model #12-1015, serial #19871. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect the employee from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PRECISION STAMPING PRODUCTS, INC.
SCHILLER PARK, IL—2017-05-17 00:00:00
PRECISION STAMPING PRODUCTS, INC.
SCHILLER PARK, IL—2008-09-25 00:00:00
PRECISION STAMPING PRODUCTS, INC.
SCHILLER PARK, IL—2008-09-17 00:00:00
PRECISION STAMPING PRODUCTS, INC.
SCHILLER PARK, IL—2004-03-23 00:00:00
PRECISION STAMPING PRODUCTS, INC.
View PRECISION STAMPING PRODUCTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332116)
SPRINGDALE, PA—2026-04-23
TECKLANE MANUFACTURING, INC.
STRATFORD, CT—2026-02-10
BLASE MANUFACTURING COMPANY
MINNEAPOLIS, MN—2026-01-07
110505 - RAO MANUFACTURING COMPANY
PINE CITY, MN—2025-12-02
110353 - M-M MANUFACTURING INC DBA PRODUCT FABRICATORS
RICHARDSVILLE, KY—2025-08-27
68342 - CANNON AUTOMOTIVE SOLUTIONS - BOWLING GREEN INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343336004.