Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOEL VELAZQUEZ-SILVA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOEL VELAZQUEZ-SILVA in 13391 CROOKED CREEK DR., CENTERVILLE, OH 45458 (NAICS 238130). OSHA activity number 343373247.

Watch Joel Velazquez-Silva — free Get an email when a new federal OSHA severe-injury report for Joel Velazquez-Silva is published. One employer, no account, unsubscribe in one click.
Site address
13391 CROOKED CREEK DR.
City
CENTERVILLE
State
OH
ZIP
45458
Mailing
25 YORK AVE., DAYTON, OH 45403
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On August 9, 2018, located on the north east side of an exterior residential roof structure, employees were installing sheathing onto a steep pitch roof as there were no frequent and regular inspections being performed by a competent person to ensure the job-site, materials and equipment such as a fall protection systems and/or devices were being maintained and utilized in a safe condition.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records
Recent events (1)
  • — Z (S) $3880

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On August 9, 2018, located on  the north east side of an exterior residential roof structure, employees were observed installing sheathing onto a steep pitch roof not utilizing an adequate fall protection system. Potential fall height was measured to be 12'-5" with a roof pitch of 10/12.