HARTFORD, SD —
OSHA Inspection: CEMCAST PIPE AND PRECAST, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CEMCAST PIPE AND PRECAST, LLC in 26088 466TH AVENUE, HARTFORD, SD 57033 (NAICS 327332). OSHA activity number 343391009.
Where did this inspection happen?
- Establishment
- CEMCAST PIPE AND PRECAST, LLC
- Site address
- 26088 466TH AVENUE
- City
- HARTFORD
- State
- SD
- ZIP
- 57033
- Mailing
- 26088 466TH AVENUE, HARTFORD, SD 57033
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327332
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $3628.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Cemcast Pipe and Precast, LLC at 26088 466th Avenue, Harford, SD 57033: On or about and at times prior to August 16, 2018, the employer did not ensure employees were exposed to hazards associated with respirator use in that the employer did not provide a medical evaluation to employees prior to the employee being required to used a respirator when performing work. This exposed employees to hazards associated with respirator use.
Recent events (2)
- — I (O) $2500
- — Z (S) $3628
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Cemcast Pipe and Precast, LLC at 26088 466th Avenue, Harford, SD 57033: On or about and at times prior to August 16, 2018, the employer did not ensure employees were protected from chemical hazards in that the company did not ensure employees passed a fit test prior to being required to wear a respirator to perform work. This exposed employees to chemical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) Cemcast Pipe and Precast, LLC at 26088 466th Avenue, Harford, SD 57033: On or about and at times prior to August 16, 2018, the employer did not ensure employees were protected from chemical hazards in that the employees were allowed to use tight fitting respirators with visible facial hair growth that would prevent a seal between the face piece and the face. This condition exposed employees to chemical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- Abate by
- Penalty
- Initial $3628.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a forklift: (a) Cemcast Pipe and Precast, LLC at 26088 466th Avenue, Harford, SD 57033: On or about and at times prior to August 16, 2018, the employer did not ensure employees were protected from hazards associated with the operation of a forklift in that the employer did not ensure each employee operating forklifts for production purposes had successfully completed training required by paragraph (l). This condition exposed employees to hazards associated with forklift operation.
Recent events (2)
- — I (O) $2500
- — Z (S) $3628
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4837.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by pinch points and rotating parts: (a) Cemcast Pipe and Precast, LLC at 26088 466th Avenue, Harford, SD 57033: On or about and at times prior to August 16, 2018, the employer did not ensure employees were protected from pinch-point hazards in that the skip hoist was not guarded to prevent employee exposure to pinch-point hazards created by rotation of the bucket wheels on the roller-track that was within 10 inches of the pit guardrail. This condition exposed employees to pinch-point hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4837
More inspections in this industry (NAICS 327332)
BILLINGS, MT—2026-05-18
RINKER MATERIALS LLC
ATLANTIC BEACH, FL—2026-05-05
NEW SOUTH CONSTRUCTION
SPOKANE, WA—2026-05-04
WA317991042 - SPOKANE WILBERT VAULT CO
SPOKANE, WA—2026-04-06
WA317990611 - SPOKANE WILBERT VAULT CO
GREENFIELD, IN—2026-02-18
RINKER MATERIALS
More inspections in SD
CLEAR LAKE, SD—2026-07-15
AEROTEK
YANKTON, SD—2026-07-14