OSHA Inspection: DENNIS GROUP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DENNIS GROUP, LLC in 216 SOUTHGATE DRIVE, MINSTER, OH 45865 (NAICS 333249). OSHA activity number 343416970.

Watch Dennis Group, LLC — free Get an email when a new federal OSHA severe-injury report for Dennis Group, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DENNIS GROUP, LLC
Site address
216 SOUTHGATE DRIVE
City
MINSTER
State
OH
ZIP
45865
Mailing
1537 MAIN STREET, SPRINGFIELD, MA 01103
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
3
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $8619.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    a) Dennis Group, LLC, at the address of 216 Southgate Drive in Minster, Ohio:  On or about August 22, 2018, the employer did not ensure energy isolating procedures were documented and/or utilized prior to replacing valve 282AV1342 that was part of a new process installation at Danone North Americas plant, exposing employees to hazards from uncontrolled energy sources.
Recent events (2)
  • — I (S) $8619
  • — Z (S) $13260

1910.147 F03 II

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4):  a) Dennis Group, LLC at the address of 216 Southgate Drive in Minster Ohio; On or about August 22, 2018, the employer did not ensure group lock out devices were affixed to pneumatic disconnects prior to performing service and maintenance activities in Danone North Americas Plant. IMS employees replacing the cluster valve body of valve 282AV1342 were exposed to hazards associated with high temperature liquids in that valve 282AV1230 was not isolated and locked out by an employee of Dennis Group. An employee suffered second and third degree burns to their arms, legs and mid-section when valve 282AV1230 was pulsed upstream and emptied into the drain been where the employee was working.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DENNIS GROUP, LLC's full OSHA safety record →