Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRIPLE SERVICE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TRIPLE SERVICE, INC. in 1220 BURLINGTON STREET, MENDOTA, IL 61342 (NAICS 238910). OSHA activity number 343472882.

Watch Triple Service, INC. — free Get an email when a new federal OSHA severe-injury report for Triple Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1220 BURLINGTON STREET
City
MENDOTA
State
IL
ZIP
61342
Mailing
801 MONROESTREET, MENDOTA, IL 61342
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3326.00 · Current $1940.00 Reduced
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    a. On or about September 18, 2018, at the above referenced inspection site, employees were required to work in a trench approximately 6 feet in depth. The employer failed to ensure material (spoil pile) was kept at least 2 feet from excavation edge. Employees were thereby exposed to struck-by hazards.    b. On or about September 18, 2018, at the above referenced inspection site, employees were required to work in a trench approximately 6 feet in depth. The employer failed to ensure material (PVC pipe) was kept at least 2 feet from excavation edge. Employees were thereby exposed to struck-by hazards.    Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3326

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2260.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section.    a. On or about September 18, 2018, at the above referenced inspection site, employees were required to work in a trench approximately 6 feet in depth. The employer failed to ensure employees were protected from cave-in by design or the use of protective barriers. Employees were thereby exposed to struck-by hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2260
  • — Z (S) $3880

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343472882.