Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PINEY BRANCH MOTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PINEY BRANCH MOTORS, INC. in 1346 4TH STREET, SE, WASHINGTON, DC 20003 (NAICS 238170). OSHA activity number 343490322.

Watch Piney Branch Motors, INC. — free Get an email when a new federal OSHA severe-injury report for Piney Branch Motors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1346 4TH STREET, SE
City
WASHINGTON
State
DC
ZIP
20003
Mailing
9299 WASHINGTON BLVD NORTH, SAVAGE, MD 20763
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
109
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4989.00 · Current $3200.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a) Office Trailer - Employees were using a Ryobi portable electric circular saw to cut vinyl skirting and a ground fault circuit interrupter was not provided, 110 volt, 15 amp service, on or about 09/26/2018.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $3200
  • — Z (S) $4989

1926.416 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) Office Trailer - Employees were using a Ryobi portable electric saw to cut vinyl skirting and the flexible cord was frayed, 110 volt, 15 amp service, on or about 09/26/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4989.00 · Current $3200.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) Office Trailer - Employees were using an extension cord that was missing a ground pin, to supply power to a Ryobi portable electric circular saw that was used to cut vinyl skirting, 110 volt, 15 amp service, on or about 09/26/2018.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $3200
  • — Z (S) $4989

1926.405 G02 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) Office Trailer - Employees were using an extension cord that was showing a strain at the plug, to supply power to a Ryobi portable electric circular saw that was used to cut vinyl skirting, 110 volt, 15 amp service, on or about 09/26/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

MACY'S