Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOGOPLASTE USA SYRACUSE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LOGOPLASTE USA SYRACUSE in 1 OLIVE GROVE STREET, ROME, NY 13441 (NAICS 326160). OSHA activity number 343507893.

Watch Logoplaste USA Syracuse — free Get an email when a new federal OSHA severe-injury report for Logoplaste USA Syracuse is published. One employer, no account, unsubscribe in one click.
Site address
1 OLIVE GROVE STREET
City
ROME
State
NY
ZIP
13441
Mailing
1 OLIVE GROVE STREET, ROME, NY 13441
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
24
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $2772.00 Reduced
29 CFR 1910.147(c)(4)(i): The employer must ensure procedures are developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in activities covered by this section:      a) Logoplaste USA Syracuse, LLC., on or about 10/3/2018: The employer did not ensure the lockout procedure was utilized as devices were not affixed to each energy source of the Sidel Blow Molding Machine, SIDEL SBO4  1 prior to an employee performing weekly maintenance, while having hands inside the machine.      b) Logoplaste USA Syracuse, LLC., on or about 10/3/2018: The employer did not ensure the lockout procedure was utilized as devices were not affixed to each energy source of the SBO4 2 prior to an employee performing weekly maintenance, while having hands inside the machine.
Recent events (2)
  • — I (S) $2772
  • — Z (S) $3696

1910.147 C06 I

Deleted Repeat Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $8130.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     a)  Logoplaste USA Syracuse, LLC., on or about 10/3/2018:   The employer had not conducted a periodic inspection of their energy control procedures. Authorized employees perform servicing and maintenance activities on equipment including, but not limited to Conair Grinders, DYCO Bagger, Kautex Blow Molding Machines, etc., which have multiple energy sources including pneumatic, hydraulic, electric and thermal.   LOGOPLASTE USA SYRACUSE, LLC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, SECTION 29 CFR 1910.147(C)(6)(I)  WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1098700, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED ON 10/28/2015, WITH RESPECT TO A WORKPLACE LOCATED AT 1 OLIVE GROVE STREET, ROME, NY, AND WAS AFFIRMED AS A FINAL ORDER ON 11/20/2015
Recent events (2)
  • — I (R) $0
  • — Z (R) $8130

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343507893.