WASHINGTON, DC —
OSHA Inspection: 727 HOBART PLACE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 727 HOBART PLACE LLC in 728-730 COLUMBIA RD NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 343522140.
Where did this inspection happen?
- Establishment
- 727 HOBART PLACE LLC
- Site address
- 728-730 COLUMBIA RD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 1230 31 STREET NW, WASHINGTON, DC 20007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $3410.00 · Current $2046.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about October 5, 2018; throughout the site; employees were exposed to a struck by hazard while operating a pneumatic Paslode nail gun and a portable Makita saw without eye protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $2046
- — Z (S) $3410
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2427.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about October 5, 2018; roof area of new edition; employees were walking the top-plate without fall protection to protect them from falling 30-35 feet to ground level. b) On or about October 5, 2018; second floor; employees were working near floor openings such as but not limited to the stair opening that was not guarded, exposing them to a 10-foot fall to the lower level. c) On or about October 5, 2018; second-floor area; employees were working near unguarded wall openings, exposing them to a 20-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2427
- — Z (S) $3978
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2427.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. a) On or about October 5, 2018; Second-floor area; Employees used a 6-foot step ladder to access the roof/top plate which was 4-feet below the platform, exposing employees to a potential 10-foot fall to the lower wooden floor or 20-feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2427
- — Z (S) $3978
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step a) On or about October 5, 2018; second floor area; employees were using a 6- foot step-ladder to access the roof/top-plate area which was located 10-feet above exposing them to a fall hazard while using the top-step of the step ladder. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about October 5, 2018; throughout the site; the employer did not certify fall protection training where employees were exposed to fall hazards of up to 30 feet while framing a house under construction. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343522140.