Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUY ORIANI CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUY ORIANI CONSTRUCTION LLC in 2067 EAST AURORA ROAD, TWINSBURG, OH 44087 (NAICS 238910). OSHA activity number 343531729.

Watch GUY Oriani Construction LLC — free Get an email when a new federal OSHA severe-injury report for GUY Oriani Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2067 EAST AURORA ROAD
City
TWINSBURG
State
OH
ZIP
44087
Mailing
11750 BRIARWOOD DRIVE, CHESTERLAND, OH 44026
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1109.00 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part:     On or about October 10, 2018 during commercial trenching and excavation activities, the employer did not have a safety and health program implemented at the worksite. The employer did not ensure employees were provided safety and health training or that there was a system in place to recognize and correct unsafe working conditions.
Recent events (2)
  • — I (S) $1108.8
  • — Z (S) $2772

1926.651 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1109.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:    On or about October 10, 2018 during commercial trenching and excavation activities, the employer did not have a competent person perform a daily inspection of the excavation prior to performing work in an excavation. The employer did not ensure a competent person was on site during excavation work.
Recent events (2)
  • — I (S) $1108.8
  • — Z (S) $2772

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  On or about October 10, 2018 during commercial trenching and excavation activities, the employer did not ensure employees working in an excavation approximately 7 feet deep were protected from cave ins by an adequate protective system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0