OSHA Inspection: ROBERT (BOB) SIMONSON

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROBERT (BOB) SIMONSON in 6 EAST CHESTNUT STREET, WILKES BARRE, PA 18702 (NAICS 238160). OSHA activity number 343549309.

Watch Robert (BOB) Simonson — free Get an email when a new federal OSHA severe-injury report for Robert (BOB) Simonson is published. One employer, no account, unsubscribe in one click.
Site address
6 EAST CHESTNUT STREET
City
WILKES BARRE
State
PA
ZIP
18702
Mailing
60 TAMARAC ROAD, PLAINS TOWNSHIP, PA 18702
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Residential Building, 6 East Chestnut Street, Wilkes-Barre, PA - An employee on the 12:12 pitch portion of the main roof was engaged in roof replacement activities without any means of fall protection and was exposed to a thirty (30) foot fall hazard, as observed on or about October 22, 2018.  In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1663.00 · Current $1663.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.  a) Residential Building, 6 East Chestnut Street, Wilkes-Barre, PA - Employees used a 40-foot Type I Werner Aluminum D-Rung Extension Ladder - Model D1340-2 or a 40-foot Type 1 Louisville Aluminum Extension Ladder - Model AE3240 for roof access/egress with fly section side rails that each extended fourteen (14) inches above the roof edge exposing the employees to a fall hazard, as observed on or about October 22, 2018.  In accordance with 29 CFR 1903.19, abatement certification is not required for this violation as the hazardous condition was corrected during the inspection.