Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAL ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAL ENTERPRISES, INC. in 520 ROTARY STREET, HAMPTON, VA 23661 (NAICS 336611). OSHA activity number 343560595.

Watch JAL Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for JAL Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
520 ROTARY STREET
City
HAMPTON
State
VA
ZIP
23661
Mailing
520 ROTARY STREET, HAMPTON, VA 23661
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2513.00 · Current $1759.00 Reduced
29 CFR 1910.101(b): 29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) in use were not properly supported to prevent them from being knocked over:  a)    JAL Enterprises dba The Source, Shop: On or about 10/12/2018, an argon cylinder used to tungsten inert gas weld stainless steel plate to a dishwasher machine was not properly supported to prevent it from being knocked over.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1759.1
  • — Z (S) $2513

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2513.00 · Current $1759.00 Reduced
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  a)    JAL Enterprises dba The Source, Weld Shop: On or about 10/12/2018, an employee required to wear a half face tight-fitting respirator during stainless steel welding was not provided with an annual fit test as a result was possible overexposed to chromium VI.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1759.1
  • — Z (S) $2513

1910.134 K

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a)     JAL Enterprises dba The Source, Shop: On or about 10/26/2018, employees required to wear a tight-fitting respirator during welding operations were not provide with annual respiratory protection training.     Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.1026 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2513.00 · Current $1759.00 Reduced
29 CFR 1915.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI  a)    JAL Enterprises dba The Source, Shop: On or about 10/12/2018, an employee welded with 316L stainless steel that according to the safety datasheet contained approximately 16-19 percent chromium. The employee's 8-hour time-weight average exposure was not determined therefore employees were potentially overexposed to toxic fumes.  Note: The employer is to make this determination in accordance with either paragraph (d)(2), the scheduled monitoring option, or paragraph (d)(3), the performance-oriented option.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1759.1
  • — Z (S) $2513

1910.1200 H03 IV

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv): Employees had not been provided with GHS 2012 training including an explanation of the labels received on shipped containers and the workplace labeling system to be used by their employer; the safety data sheet, including the order of information, and how employees can obtain and use the appropriate hazard information:  a)    JAL Enterprises dba The Source: On or about 10/26/2018, employees required to use Kleen Brite and other chemicals were not provided with the new GHS training.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.132 D

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.132(d): Worn or frayed electric cables shall not be used.  a)    JAL Enterprises dba The Source, Weld Shop: On or about 10/26/2018, a Milwaukee 4.5 inch electrical sander-grinder, serial #6148 had a frayed cord and black tape was applied over the outer jacket to cover the damage.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343560595.