Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GTM MANUFACTURING LLC DBA KGTM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GTM MANUFACTURING LLC DBA KGTM in 2100 SPRUCE, AMARILLO, TX 79103 (NAICS 332420). OSHA activity number 343567616.

Watch GTM Manufacturing LLC DBA Kgtm — free Get an email when a new federal OSHA severe-injury report for GTM Manufacturing LLC DBA Kgtm is published. One employer, no account, unsubscribe in one click.
Site address
2100 SPRUCE
City
AMARILLO
State
TX
ZIP
79103
Mailing
P.O. BOX 31598, AMARILLO, TX 79103
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.184 H01

Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $4546.00 · Current $2728.00 Reduced
29 CFR 1910.184(h)(1):  Natural and synthetic fiber-rope slings did not have permanently affixed and legible identification markings stating the rated capacity for the type(s) of hitch(es) used and the angle upon which it was based, type of fiber material, and the number of legs if more than one:    a)  At the facility, the slings used to move heavy metal products did not have legible identification markings.
Recent events (2)
  • — I (S) $2727.6
  • — Z (S) $4546

1910.184 H05 III

Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service:  a)  At the facility, the rope slings being used to move cylinders were frayed and torn, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a)  At the facility, the ACRA Drill Press, 12 speed, MD 32MMF 2006, Serial Number 1215903, was not anchored to floor to prevent walking or moving, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.303 G01

Serious Gravity 1 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  a)  At the facility, electrical panel and breaker boxes were blocked by shop vacuums, dryer, fans, mop buckets and trash and debris exposing employees to electrical shock and burn hazards.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.157 E03

Other-than-serious 8 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: On or about October 24, 2019, at KGTM Gas Transport Modules located at 2100 Spruce, Amarillo, Texas 79120, employees were exposed to burns and struck-by hazards:  a)  At the second column on pipe side, the portable fire extinguisher had not bee inspected annually.  b)  At the third column northeast on pipe side, the portable fire extinguisher had not bee inspected annually.  c)  At the east side of Frame Shop center, the portable fire extinguisher had not bee inspected annually.  d)  At the north end of meeting room by stairs, the portable fire extinguisher had not bee inspected annually.  e)  At the south by exit door, the portable fire extinguisher had not bee inspected annually.  f)  At north center by changing area, the portable fire extinguisher had not bee inspected annually.  g)  At west side outside by door in winding room, the portable fire extinguisher had not bee inspected annually.   h)  At east wall in winding room, the portable fire extinguisher had not bee inspected annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View GTM MANUFACTURING LLC DBA KGTM's full OSHA safety record →