OSHA Inspection: SRC VENTURES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SRC VENTURES, LLC in 6450 JIMMY CARTER BOULEVARD, NORCROSS, GA 30071 (NAICS 238110). OSHA activity number 343570594.

Watch SRC Ventures, LLC — free Get an email when a new federal OSHA severe-injury report for SRC Ventures, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SRC VENTURES, LLC
Site address
6450 JIMMY CARTER BOULEVARD
City
NORCROSS
State
GA
ZIP
30071
Mailing
P.O. BOX 387, BROOKS, GA 30205
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3220.00 · Current $1932.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.   On or about and days prior to October 30, 2018:  Employees wet cutting and working in the enclosed area of the warehouse located at 6450 Jimmy Carter Boulevard in Norcross, Georgia are required to wear a 3M 8210 Plus N95 Respirator.  The employer did not ensure that employees had been medically evaluated.
Recent events (2)
  • — I (S) $1932
  • — Z (S) $3220

1910.134 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator.   On or about and days prior to October 30, 2018:  Employees wet cutting and working in the enclosed area of the warehouse located at 6450 Jimmy Carter Boulevard in Norcross, Georgia are required to wear a 3M 8210 Plus N95 Respirator.  The employer did not ensure that employees had been fit tested prior to initial use.