ALEXANDRIA, LA —
OSHA Inspection: JEANSONNE'S MILLWORK, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of JEANSONNE'S MILLWORK, INC. in 1843 STERKX RD, ALEXANDRIA, LA 71301 (NAICS 321918). OSHA activity number 343584595.
Where did this inspection happen?
- Establishment
- JEANSONNE'S MILLWORK, INC.
- Site address
- 1843 STERKX RD
- City
- ALEXANDRIA
- State
- LA
- ZIP
- 71301
- Mailing
- 1843 STERKX RD, ALEXANDRIA, LA 71301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1330.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): Places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: On or about November 7, 2018, in the shop area, the employer allowed employees to be exposed to dust accumulated outside of the dust collection systems, which posed as a fire, deflagration, or explosion hazard.
Recent events (2)
- — I (S) $1330.4
- — Z (S) $1663
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1330.00 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about November 7, 2018, in the shop where employees are expected to extinguish incipient level fires, the employer allowed employees to stack material and block access to five (5) unidentified fire extinguishers.
Recent events (2)
- — I (S) $1330.4
- — Z (S) $1663
1910.213 C01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3104.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: On or about November 7, 2018, in the shop area, the employer failed to ensure that circular hand-fed ripsaws were equipped with an appropriate hood or barrier guard prior to allowing employees to perform woodcutting tasks in the following instances: a) Wadkin Table Saw, and b) Powermatic D40 Table Saw.
Recent events (2)
- — I (S) $3104
- — Z (S) $3880
1910.213 C02
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(2): Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: On or about November 7, 2018, in the shop area, the employer failed to ensure that circular hand-fed ripsaws were equipped with an appropriate riving knife or spreader prior to allowing employees to perform woodcutting tasks in the following instances: a) Wadkin Table Saw, and b) Powermatic D40 Table Saw.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1910.213 C03
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: On or about November 7, 2018, in the shop area, the employer failed to ensure that circular hand-fed ripsaws were equipped with appropriate dogs or anti-kickback pawls prior to allowing employees to perform woodcutting tasks in the following instances: a) Wadkin Table Saw, and b) Powermatic D40 Table Saw.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $1774.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: On or about November 7, 2018, in the shop where wood dust accumulated, the employer failed to ensure three (3) 240V AC 3-Phase Main Circuit Breaker electrical panels were closed to prevent electric shock, deflagration, or other fire hazards.
Recent events (2)
- — I (S) $1773.6
- — Z (S) $2217
More inspections at JEANSONNE'S MILLWORK, INC.
ALEXANDRIA, LA—2007-05-10 00:00:00
JEANSONNE'S MILLWORK, INC.
View JEANSONNE'S MILLWORK, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
WALNUT GROVE, KY—2026-07-07
69295 - MENZNER HARDWOODS CO
DEERWOOD, MN—2026-07-02
111521 - ACORN MILLWORK INC
MONTELLO, WI—2026-06-30
FLOORING AND EQUIPMENT LLC
LENOIR, NC—2026-06-26
161438 - WOODGRAIN, INC.
SALEM, MO—2026-06-09
CANOAK MISSOURI, LLC
More inspections in LA
LAFAYETTE, LA—2026-07-15
GULLEY'S WELDING & STEEL ERECTORS, INC.
LAFAYETTE, LA—2026-07-15
ACORREA COMPANY, LLC
LAFAYETTE, LA—2026-07-14
GULF COAST WOODWORK, L.L.C.
BELLE ROSE, LA—2026-07-14
OXYCHEM
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
Source