ARCOLA, TX —
OSHA Inspection: TOLSON ENTERPRISES, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TOLSON ENTERPRISES, LLC in 503 MCKEEVER RD. #1504, ARCOLA, TX 77583 (NAICS 488190). OSHA activity number 343613352.
Where did this inspection happen?
- Establishment
- TOLSON ENTERPRISES, LLC
- Site address
- 503 MCKEEVER RD. #1504
- City
- ARCOLA
- State
- TX
- ZIP
- 77583
- Mailing
- 503 MCKEEVER RD. #1504, ARCOLA, TX 77583
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 13
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $2957.00 Reduced
068906941377
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At the facility: On or about November 20, 2018 employees painting and sanding aircrafts were required to use respiratory protection and a written program including provisions for selection, cartridge change, use, training, fit testing and medical evaluation was not established and implemented.
Recent events (2)
- — I (O) $2956.8
- — Z (S) $3696
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At the facility: On or about November 20, 2018 employees who were required to wear tight fitting air purifying respirators during painting were not medically evaluated to determine their ability to use the respirator.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator or annually thereafter: a) At the facility: On or about November 20, 2018 employees using tight fitting air purifying respirators during painting were not fit tested.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 D01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) At the facility: On or about November 20, 2018 the employer did not make reasonable estimate of employee exposure during spray painting with coatings containing multiple chemicals including but not limited to Hexamethylene Diisocyanate (NIOSH REL 0.02 ppm), propylene glycol methyl ether (NIOSH REL 150 ppm), and ethyl benzene (PEL 100 ppm).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 D03 III B 2
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
069410731377
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life: At the facility: On or about November 20, 2018 the employer did not implement a cartridge change schedule based on objective data such as exposure assessment data, exposing employees to a potential inhalation hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
069410731377
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a) At the facility: On or about November 20, 2018 employees required to wear tight fitting air purifying respirators during painting were not provided initial and annual training on the proper use and limitations of the respirators.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1026 D02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area: a) At the facility: On or about November 20, 2018 the employer did not determine the 8 hour time weighted average exposure to chromium (VI) when employees mixed and sprayed Sherwin Williams CM04833660 green primer containing strontium chromate, a source of chromium (VI) (PEL 0.005 mg/m3).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Penalty
- Initial $3696.00 · Current $2218.00 Reduced
069410731377
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(e)(1)(i), (f), (g), and (h) will be met: a) At the facility: On or about November 20, 2018 the employer did not develop or implement a written hazard communication program when employees used hazardous chemicals in the workplace including but not limited to strontium chromate, isocyanates, and ethyl benzene.
Recent events (2)
- — I (O) $2217.6
- — Z (S) $3696
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $2956.00 · Current $1774.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. a) At the facility: On or about November 20, 2018 employees were exposed to an electrical shock hazard when turning the paint spray exhaust fan circuit breaker on and off from a 110 volt distribution panel that had several blanks missing.
Recent events (2)
- — I (S) $1773.6
- — Z (S) $2956
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) At the facility: On or about November 20, 2018, located on the north wall of the hanger outside the employee lunch room door where employees were exposed to a shock hazard when using a 110 volt electrical outlet box that was bent and broken exposing conductor wires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 488190)
VANDALIA, OH—2026-07-08
SIERRA NEVADA CORPORATION
ASPEN, CO—2026-06-17
ATLANTIC AVIATION-MONTROSE LLC
GULF SHORES, AL—2026-06-17
TREGO/DUGAN AVIATION OF GRAND ISLAND, INC.
LOS ANGELES, CA—2026-06-12
UNITED AIRLINES
DORAL, FL—2026-05-28
FLIGHT POWER REPAIR GROUP, LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343613352.